Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

ІТМ-111, ІТМ-111В — single-channel microprocessor process indicator

error ≤ 0.2 % · measurement time ≤ 0.1 s · RS-485, Modbus RTU · supply 100–242 V AC / 18–36 V DC

The ІТМ-111 is a single-channel microprocessor indicator of process parameters for panel mounting. It accepts standard current and voltage signals, resistance thermometer inputs (ТСМ, ТСП, Pt100–Pt1000), thermocouples of types K, L, J, S, B, E and A-1, as well as 0–1 kΩ resistance and NTC sensors. The instrument processes the signal and shows the value on a four-digit seven-segment LED display. Basic error does not exceed 0.2 % and measurement time is no more than 0.1 s. The input is galvanically isolated (≥ 500 V), while the outputs and interface are isolated at ≥ 1500 V. It provides two discrete outputs (transistor, relay or solid-state), an optional analogue output and an RS-485 port with Modbus RTU. Supply is 100–242 V AC or 18–36 V DC, and the operating temperature range is −40 to +70 °С. Typical applications are energy, metallurgy, and the chemical and food industries. The model has been discontinued and is replaced by the ІТМ-311. Discontinued. Current replacement: ІТМ-311.

Input signal types
0–5 mA, 0–20 mA, 4–20 mA, 0–10 V, 0–75 mV, 0–200 mV, 0–2 V, ТСМ 50М, ТСМ 100М, ТСП 50П, ТСП 100П, Pt100, Pt500, Pt1000, ТХА (K), ТХК (L), ТЖК (J), ТПП 10 (S), ТПР (B), ТХКн (E), ТВР-1 (A-1), 0–1 kΩ, NTC
Number of analogue inputs
1
Measurement error
≤ 0.2 %
Measurement time
≤ 0.1 s

Technical specifications

Input signal types0–5 mA, 0–20 mA, 4–20 mA, 0–10 V, 0–75 mV, 0–200 mV, 0–2 V, ТСМ 50М, ТСМ 100М, ТСП 50П, ТСП 100П, Pt100, Pt500, Pt1000, ТХА (K), ТХК (L), ТЖК (J), ТПП 10 (S), ТПР (B), ТХКн (E), ТВР-1 (A-1), 0–1 kΩ, NTC
Number of analogue inputs1
Measurement error≤ 0.2 %
Measurement time≤ 0.1 s
Galvanic isolation voltage≥ 500 V (input), ≥ 1500 V (outputs/interface)
Analogue output (option)0–5 mA (R ≤ 2000 Ω), 0–20 mA (R ≤ 500 Ω), 4–20 mA (R ≤ 500 Ω), 0–10 V (R ≤ 2 kΩ)
Discrete outputs2
Discrete output typestransistor (≤ 40 V, 100 mA), relay (≤ 230 V, 8 A), solid-state (≤ 60 V, 1 A)
InterfaceRS-485
ProtocolModbus RTU (Slave, Master)
Display4-digit 7-segment LED
Analogue bar scale31 segments (ІТМ-111), 21 segments (ІТМ-111В)
Supply voltage AC100–242 V
Supply voltage DC18–36 V
Power consumption AC≤ 6.5 VA
Current consumption DC≤ 180 mA
Mountingpanel
Panel cutout92+0.8 × 45+0.6 mm
Front panel48×96 mm, horizontal (ІТМ-111); 96×48 mm, vertical (ІТМ-111В)
Dimensions48×96×141 mm
Weight≤ 0.35 kg
Protection degreeIP30
Operating temperature−40…+70 °С
StandardsГОСТ 26.011-80, ДСТУ 2858-94, ГОСТ3044-94, DIN IEC 584-1, ГОСТ 22261
Statusdiscontinued, current replacement: ІТМ-311

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

The ІТМ-111 version has a horizontal 48×96 mm front panel and a 31-segment analogue scale. The ІТМ-111В has a vertical 96×48 mm panel and 21 segments. Select the discrete output type to suit the load: transistor (≤ 40 V, 100 mA), relay (≤ 230 V, 8 A) or solid-state (≤ 60 V, 1 A). The analogue output is optional. For new projects the ІТМ-311 is recommended.

Similar products

Test and measurement

Request a price and lead time

ІТМ-111, ІТМ-111В — single-channel microprocessor process indicator. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.