ІТМ-115 — single-channel process indicator with circular scale

error ≤ 0.2 % · measurement time up to 0.1 s · 4 discrete outputs · RS-485, Modbus RTU

The ІТМ-115 is a single-channel microprocessor process indicator for measuring and displaying temperature, pressure, flow, level and other physical quantities. It accepts the signal of one sensor: standard current 0-5, 0-20 or 4-20 mA, voltage from 0-50 mV to 0-10 V, resistance thermometers (ТСМ, ТСП, Pt100/Pt500/Pt1000), thermocouples (K, L, J, S, B, E, A-1), resistance and NTC sensors. The measured value is shown on a four-digit seven-segment display and duplicated on a circular scale. The measurement error limit is ≤ 0.2 % (≤ 0.25 % for thermocouples), the measurement time is up to 0.1 s and the galvanic isolation voltage is not less than 500 V. The unit provides 4 discrete outputs (NPN transistor, relay or optotriac), an optional analogue output and an RS-485 interface with Modbus RTU for integration into automation systems. It is powered from 230 V AC or 24 V DC and operates from -40 °С to +70 °С. Typical applications include energy, metallurgy, and the chemical and food industries.

Device type
process indicator
Number of analogue inputs
1
Input signals (current, voltage)
0-5 mA, 0-20 mA, 4-20 mA, 0-10 V, 0-50 mV, 0-200 mV, 0-2 V
Input signals (resistance thermometers)
ТСМ 50М, ТСМ 100М, ТСП 50П, ТСП 100П, Pt100, Pt500, Pt1000

Technical specifications

Device typeprocess indicator
Number of analogue inputs1
Input signals (current, voltage)0-5 mA, 0-20 mA, 4-20 mA, 0-10 V, 0-50 mV, 0-200 mV, 0-2 V
Input signals (resistance thermometers)ТСМ 50М, ТСМ 100М, ТСП 50П, ТСП 100П, Pt100, Pt500, Pt1000
Input signals (thermocouples)ТХА (K), ТХК (L), ТЖК (J), ТПП 10 (S), ТПР (B), ТХКн (E), ТВР -1(A-1)
Input signals (resistance)0-1 kΩ, NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)
Measurement error limit≤ 0.2 %, ≤ 0.25 % (for thermocouples)
Measurement timeup to 0.1 s
Galvanic isolation voltagenot less than 500 V
Number of analogue outputs1 (option)
Analogue output signals0–5 mA / R ≤ 2000 Ω, 0–20 mA / R ≤ 500 Ω, 4–20 mA / R ≤ 500 Ω, 0–10 V / R ≤ 2 kΩ
Output signal error limit≤ 0.2 %
Number of discrete outputs4
Discrete output typesNPN transistor: up to 40 V, 100 mA; relay: up to 230 V, 8 A; optotriac: up to 300 V, 0.7 A
InterfaceRS-485
ProtocolModbus RTU
Displayseven-segment digital display, circular scale
Display resolution4 digits
Supply voltage (AC)230 V
Supply voltage (DC)24 V
Power consumption (AC)≤ 8.5 VA
Current consumption (DC)250 mA
Mounting (ІТМ-115)panel
Dimensions (HxWxD), ІТМ-11596х96х120 mm
Weight, ІТМ-115not more than 0.6 kg
Protection degree, ІТМ-115IP30
Mounting (ІТМ-115Т)panel, DIN rail, wall
Dimensions, ІТМ-115Т145х120х80 mm
Weight, ІТМ-115Тnot more than 0.7 kg
Protection degree, ІТМ-115ТIP65
Operating temperaturefrom -40 °С to +70 °С

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

The basic ІТМ-115 is intended for panel mounting (96х96х120 mm, IP30). For DIN-rail or wall installation and conditions requiring better protection, choose the ІТМ-115Т (145х120х80 mm, IP65). Select the discrete output type by load: NPN transistor up to 40 V/100 mA, relay up to 230 V/8 A, optotriac up to 300 V/0.7 A. Supply is 230 V AC or 24 V DC; the analogue output is optional.

Similar products

Test and measurement

Request a price and lead time

ІТМ-115 — single-channel process indicator with circular scale. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.