ІТМ-115Т — single-channel process indicator with circular scale

accuracy ≤ 0.2 % · RS-485, Modbus RTU · IP65 · −40…+70 °C

The ІТМ-115Т is a single-channel microprocessor indicator for measuring and displaying process variables such as temperature, pressure, flow and level. It accepts standard current and voltage signals, as well as inputs from resistance thermometers, thermocouples, resistive sensors and NTC thermistors. The reading is shown simultaneously on a 4-digit 7-segment display and on a circular analogue scale, making it easy to follow how a parameter is changing at a glance. Accuracy is ≤ 0.2 % (≤ 0.25 % for thermocouples), response time is ≤ 0.1 s and galvanic isolation voltage is ≥ 500 V. An RS-485 interface with Modbus RTU links the unit to supervisory systems, while an analogue output and four discrete outputs (NPN transistor or relay) are available as options. The IP65 enclosure operates from −40 °C to +70 °C. Typical applications include power generation, metallurgy, and the chemical and food industries.

Input signals (standard)
0–5 mA, 0–20 mA, 4–20 mA, 0–10 V, 0–50 mV, 0–200 mV, 0–1 V
Resistance thermometers
TSM 50M, TSM 100M, TSP 50P, TSP 100P, Pt100, Pt500, Pt1000
Thermocouples (type)
K, L, J, E, S, B, A-1
Resistance / NTC
0–1000 Ohm; NTC 1 kOhm, 3 kOhm, 5 kOhm, 10 kOhm

Technical specifications

Input signals (standard)0–5 mA, 0–20 mA, 4–20 mA, 0–10 V, 0–50 mV, 0–200 mV, 0–1 V
Resistance thermometersTSM 50M, TSM 100M, TSP 50P, TSP 100P, Pt100, Pt500, Pt1000
Thermocouples (type)K, L, J, E, S, B, A-1
Resistance / NTC0–1000 Ohm; NTC 1 kOhm, 3 kOhm, 5 kOhm, 10 kOhm
Temperature measuring range0…2500 °C
Accuracy≤ 0.2 %; ≤ 0.25 % (thermocouples)
Response time≤ 0.1 s
Galvanic isolation voltage≥ 500 V
Analogue output (optional)0–5 mA, 0–20 mA, 4–20 mA, 0–10 V
Discrete outputs4 × NPN transistor (≤ 40 V, 100 mA) or 4 × relay (≤ 230 V, 5 A or 8 A)
Interface / protocolRS-485 / Modbus RTU
Display4-digit 7-segment display, circular scale
Supply voltage AC100–242 V, 50 Hz
Supply voltage DC18–36 V
Power consumption AC≤ 6.5 VA
Consumption DC250 mA
MountingDIN rail, panel
Protection degreeIP65
Operating temperature−40…+70 °C
Dimensions145 x 120 x 80 mm
Weight≤ 0.7 kg
ІТМ-115 versionpanel mounting, IP30, 96x96x120 mm, ≤ 0.6 kg
Standards complianceДСТУ EN 60529:2014, ДСТУ IEC 60654-1:2001, ДСТУ IEC 60654-3:2001

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

The ІТМ-115Т (IP65, 145 x 120 x 80 mm) mounts on a DIN rail or panel; for indoor panel mounting where IP30 is sufficient, the ІТМ-115 (96x96x120 mm) is an alternative. NPN transistor outputs handle loads up to 40 V, 100 mA, whereas relay outputs handle up to 230 V, 5 A or 8 A. Supply is either 24 V DC or 220 V AC; the analogue output is optional.

Similar products

Test and measurement

Request a price and lead time

ІТМ-115Т — single-channel process indicator with circular scale. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.