ІТМ-300А — single-channel panel-mount process indicator
Country: Ukraine · Model: ІТМ-300А
accuracy ≤ 0.2 % · measurement time up to 0.1 s · galvanic isolation ≥ 500 V · RS-485, Modbus RTU
The ІТМ-300А is a single-channel microprocessor indicator for panel mounting. It measures and displays process parameters such as temperature, pressure, flow and level. Its universal analogue input accepts standard current and voltage signals, thermocouple and resistance thermometer signals, and resistance sensor signals including NTC. The measured value appears on a six-digit display. Measurement time is up to 0.1 s and accuracy is within 0.2 %. The input circuits have galvanic isolation of at least 500 V. For integration into process control systems the unit provides an RS-485 interface with Modbus RTU, plus a USB port. Optional fittings include an analogue output, relay or transistor discrete outputs and a built-in 24 V sensor supply. The unit is powered from 230 V AC or 24 V DC. It operates from -40 to +70 °C and has IP30 protection. Typical users are the power, metallurgical, chemical and food industries.
- Device type
- single-channel microprocessor indicator
- Current inputs
- 0-5 mA, 0-20 mA, 4-20 mA, -5…5 mA, -20…20 mA
- Voltage inputs
- 0-10 V, 0-100 mV, -10…10 V, -100…100 mV
- Thermocouples
- TХA, TХК, ТНН, ТЖК, ТПП10, ТПП, ТПР, ТМКн, ТХКн, ТВР-1, ТВР-2, ТВР-3
Technical specifications
| Device type | single-channel microprocessor indicator |
|---|---|
| Current inputs | 0-5 mA, 0-20 mA, 4-20 mA, -5…5 mA, -20…20 mA |
| Voltage inputs | 0-10 V, 0-100 mV, -10…10 V, -100…100 mV |
| Thermocouples | TХA, TХК, ТНН, ТЖК, ТПП10, ТПП, ТПР, ТМКн, ТХКн, ТВР-1, ТВР-2, ТВР-3 |
| Resistance thermometers | ТСМ 50М, ТСМ 100М, ТСП 50П, ТСП 100П, Pt100, Pt500, Pt1000, ТСН 100Н |
| Resistance inputs | 0-2500 Ω, 0-300 Ω, 0-1200 Ω, 0-150 Ω, NTC |
| Accuracy | ≤ 0.2 %; ≤ 0.4 % after changing sensor type without calibration |
| Measurement time | up to 0.1 s |
| Galvanic isolation | at least 500 V |
| Supply voltage | 230 V AC or 24 V DC |
| Power consumption (AC) | max. 4 VA |
| Current consumption (DC) | max. 200 mA |
| Display | six-digit |
| Interfaces | RS-485, USB |
| Protocol | Modbus RTU |
| Optional outputs | analogue (0-5 mA, 0-20 mA, 4-20 mA, 0-10 V); discrete (relay, transistor) |
| Built-in sensor supply (option) | 24 V, 25 mA |
| Protection rating | IP30 |
| Ambient temperature | -40 °C to +70 °C |
| Mounting | panel |
| Dimensions | 48 × 96 × 106 mm |
| Weight | max. 0.25 kg |
| Standard | ДСТУ IEC 60381-1 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
When ordering, choose the supply voltage: 230 V AC or 24 V DC. The input signal code is set to suit the sensor type. If the measured value must be passed to a control system, specify an analogue output (0-5 mA, 0-20 mA, 4-20 mA, 0-10 V). For alarms and control, specify discrete outputs, either relay or transistor. A built-in 24 V, 25 mA supply is available to power passive sensors.