ІТМ-4С К6 — multi-channel RS-485/Modbus RTU interface indicator
Country: Ukraine · Model: ІТМ-4С К6
8 channels · RS-485, Modbus RTU · 100–242 V AC / 18–36 V DC · -40…+70 °C
The ІТМ-4С К6 is a panel-mounted multi-channel interface indicator for remote display of up to 8 parameters received from external devices over an RS-485 line. Communication uses the Modbus RTU protocol. In Master mode the unit periodically polls connected devices and reads values from configured registers. In Slave mode it operates on the network as a subordinate node. Up to 4 independent values are shown on a 4-digit LED display. The unit is powered from a 100–242 V, 50 Hz mains supply or from an 18–36 V DC source. Galvanic isolation is rated at no less than 1500 V. Depending on the version, the indicator is fitted with 4 discrete outputs. The front panel measures 96 x 96 mm, with a mounting depth of 85 mm, IP30 protection and an operating temperature range of -40 to +70 °C. Typical applications include energy, metallurgy, and the chemical and food industries. It is also used in automation systems to bring controller and transmitter data to the operator panel.
- Device type
- Interface indicator
- Number of channels
- 8
- Display
- 4-digit LED
- Values displayed simultaneously
- up to 4
Technical specifications
| Device type | Interface indicator |
|---|---|
| Number of channels | 8 |
| Display | 4-digit LED |
| Values displayed simultaneously | up to 4 |
| Interface | RS-485 |
| Protocol | Modbus RTU (Master/Slave) |
| Discrete outputs | 4 (NPN transistor, relay or optotriac — depending on version) |
| AC supply voltage | 100 V to 242 V, 50 Hz |
| DC supply voltage | 18 V to 36 V |
| Power consumption (AC) | 7.7 VA |
| Current consumption (DC) | ≤ 250 mA |
| Galvanic isolation voltage | ≥ 1500 V |
| Memory | EEPROM, NVRAM |
| Mounting | Panel |
| Front panel size | 96 x 96 mm |
| Mounting depth | 85 mm |
| Panel cutout | 92+0.8 x 92+0.8 mm |
| Protection degree | IP30 |
| Operating temperature | -40 °C ... +70 °C |
| Weight | < 0.6 kg |
| Standards | GOST 22261, GOST 26828, GOST 12971, GOST 23170, GOST 15150-69 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Select the version by discrete output type and supply voltage. NPN transistor outputs suit controller inputs and interposing relays. Relay outputs are intended for direct switching of alarm circuits. Optotriac outputs provide contactless control of AC loads. For the supply, choose 220 V AC mains (100–242 V range) or 24 V DC (18–36 V range).
Similar products
Request a price and lead time
ІТМ-4С К6 — multi-channel RS-485/Modbus RTU interface indicator. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.