К535 — calibration device for current and voltage instrument transformers
Country: Ukraine · Model: К535
CTs of class 0.02 and lower · VTs of class 0.05 and lower · 40–1000 Hz · secondary current 0.5–5 A
The К535 is designed to calibrate current transformers of accuracy class 0.02 and lower and voltage transformers of accuracy class 0.05 and lower. It determines the error components: the ratio error (current error for CTs, voltage error for VTs) and the phase-angle error. It also measures the active and reactive components of the burden in the secondary circuit of the transformer under test. Current transformers are tested by an absolute method using the И562 comparator, so no reference transformer is needed. The device handles VTs with secondary voltages of 100:3, 100:√3, 100, 200:√3, 150 and 200 V, and CTs with secondary currents of 0.5, 1, 2, 2.5 and 5 A. Error measuring ranges are ±0.2 %, ±2 % and ±20 %, with phase-angle error measured up to ±200′. The working frequency range is 40–1000 Hz. The set consists of two benchtop units: the Ф5304 measuring unit and the И562 comparator. Power comes from a (220 ± 22) V, (50 ± 0.5) Hz mains supply, and consumption does not exceed 50 V·A. The device is used in metrology and calibration laboratories for high-precision verification of current and voltage transformers.
- Current transformers under test
- accuracy class 0.02 and lower
- Voltage transformers under test
- accuracy class 0.05 and lower
- VT rated secondary voltage
- 100:3; 100:√3; 100; 200:√3; 150; 200 V
- CT rated secondary current
- 0.5; 1; 2; 2.5; 5 A
Technical specifications
| Current transformers under test | accuracy class 0.02 and lower |
|---|---|
| Voltage transformers under test | accuracy class 0.05 and lower |
| VT rated secondary voltage | 100:3; 100:√3; 100; 200:√3; 150; 200 V |
| CT rated secondary current | 0.5; 1; 2; 2.5; 5 A |
| CT error measurement method | absolute (no reference transformer) |
| Comparator rated ampere-turns | 100; 200; 300 |
| Ratio (voltage/current) error ranges | ±0.2 %; ±2 %; ±20 % |
| Phase-angle error ranges | ±20′; ±200′ |
| Reference frequency range (filter off) | 45–100 Hz |
| Working frequency range (filter off) | 40–1000 Hz |
| Burden measuring ranges (active/reactive) | 1, 10, 100 W (var) |
| Relative secondary voltage (current) ranges | 15 and 150 % of rated |
| Fiducial error of relative voltage (current) measurement | ±1.5 % (Ф5304 display); ±2.5 % (comparator analogue meter) |
| Comparator intrinsic absolute error | ratio ±0.005 %; phase angle ±0.3′ |
| Supply voltage | (220 ± 22) V AC |
| Supply frequency | (50 ± 0.5) Hz |
| Power consumption | max. 50 V·A |
| Composition | Ф5304 measuring unit, И562 comparator (benchtop) |
| Ф5304 measuring unit dimensions | 330x150x350 mm |
| Ф5304 measuring unit weight | max. 8.5 kg |
| И562 comparator dimensions | 450x300x470 mm |
| И562 comparator weight | max. 26.5 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Select the measuring range according to the expected error of the transformer under test. Range 0.2 (±0.2 %, ±20′) suits high-accuracy CTs and VTs, while ranges 2 and 20 cover less accurate units. Set the comparator ampere-turn rating (100, 200 or 300) to match the CT's primary and secondary currents. At 300 ampere-turns, only a 5 A secondary current is available.