М2015 — portable multi-range DC voltammeter
Country: Ukraine · Model: М2015
accuracy class 0.2 · current: 0.75 mA – 30 A (15 ranges) · voltage: 45 mV and 3 V · settling time ≤ 4 s
The М2015 is a portable laboratory voltammeter with a magnetoelectric (moving-coil) mechanism. It measures current and voltage in DC circuits. A single instrument provides 15 current ranges and 2 voltage ranges. Current ranges have full-scale values from 0.75 to 75 mA and from 0.15 to 30 A. Voltage limits are 45 mV and 3 V. The 45 mV range is specified at the ends of the calibrated connecting leads supplied with the instrument. Every range meets accuracy class 0.2, with a permissible basic error of ±0.2%. Readings settle within 4 s. The insulation is tested at 2 kV. The instrument operates at ambient temperatures from +10 to +35 °C and relative humidity up to 80% at +25 °C. It weighs no more than 3.0 kg, so it is easy to move between workstations. Typical uses include laboratory work, calibration and commissioning tasks, and precise current and voltage measurements in DC circuits.
- Measuring mechanism
- magnetoelectric
- Design
- portable, multi-range
- Current type
- DC
- Accuracy class
- 0.2
Technical specifications
| Measuring mechanism | magnetoelectric |
|---|---|
| Design | portable, multi-range |
| Current type | DC |
| Accuracy class | 0.2 |
| Permissible basic error | ±0.2% (on all ranges) |
| Current range full-scale values, mA | 0.75; 1.5; 3; 7.5; 15; 30; 75 |
| Current range full-scale values, A | 0.15; 0.3; 0.75; 1.5; 3; 7.5; 15; 30 |
| Voltage ranges | 45 mV (at the ends of calibrated connecting leads); 3 V |
| Voltage drop on 0.75–75 mA ranges | 27–80 mV |
| Voltage drop on 0.15–30 A ranges | 87–230 mV |
| Full-deflection current on voltage ranges | 1 mA |
| Settling time | max. 4 s |
| Insulation test voltage | 2 kV |
| Ambient temperature | +10 to +35 °C |
| Relative humidity | up to 80% at +25 °C |
| Overall dimensions | max. 243 × 200 × 100 mm |
| Weight | max. 3.0 kg |
| Scope of delivery | voltammeter – 1 pc; calibrated connecting leads – 2 pcs; technical description and operating manual – 1 copy |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
The milliampere ranges (0.75–75 mA) suit low-current circuits, with a voltage drop of 27–80 mV. The ampere ranges (0.15–30 A) cover currents up to 30 A, with a voltage drop of 87–230 mV. Use the 45 mV range only with the calibrated connecting leads supplied. The 3 V range is for voltage measurement and has a full-deflection current of 1 mA.
Similar products
Request a price and lead time
М2015 — portable multi-range DC voltammeter. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.