Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

Megaohmmeters ES0202/1-G and ES0202/2-G (ЭС0202, ЭСО202, ЭСО 202/2Г, ЭС 0202, ESO202, ES 0202/2G), with built-in hand generator, 100–2500 V

Megaohmmeters ES0202/1-G and ES0202/2-G, often searched as ЭСО202 or ESO202, measure insulation resistance of de-energized circuits. The built-in hand-driven generator supplies the power, so no mains or batteries are needed. The /1-G reads up to 1000 MΩ at 100, 250 and 500 V, the /2-G up to 10 000 MΩ at up to 2500 V.

Range ES0202/1-G
0–1000 MΩ
Voltages ES0202/1-G
100, 250, 500 V
Range ES0202/2-G
up to 10 000 MΩ
Voltage ES0202/2-G
up to 2500 V

Technical specifications

Range ES0202/1-G0–1000 MΩ
Voltages ES0202/1-G100, 250, 500 V
Range ES0202/2-Gup to 10 000 MΩ
Voltage ES0202/2-Gup to 2500 V
Basic relative error±15 %
Power supplybuilt-in electromechanical hand-driven generator
Handle rotation speed120–144 rpm
Operating modeintermittent, 1 min measurement, 2 min pause
Operating temperature−30…+50 °C
GOST 22261 group3, with extended operating temperature range
Other spellingsЭСО202, ЭСО 202/2Г, ЭСО202/1Г, ЭС 0202/2Г, ЭС0202-2Г, ЕС0202/2-Г, ES0202/2G, ESO202, ES 0202/2G

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The instrument has a pointer scale. It applies a test voltage to the circuit and reads insulation resistance in megaohms. Discharge the circuit before testing. The generator handle turns at 120–144 rpm, so the megaohmmeter works at a substation, in a cable well or in a workshop without a power socket. Basic relative error is ±15 %. Operation is intermittent, one minute of measurement then two minutes of pause, so long cable tests need that pause built into the plan. Operating temperature from −30 to +50 °C, GOST 22261 group 3 with extended range. Used for cables, motors, transformers and acceptance tests. Its designation is written in several ways, such as ЭС0202, ЭСО202, ЭСО 202/2Г, ЭС 0202/2Г, ЭС0202-2Г, ЕС0202/2-Г or ES0202/2G, and all of them mean one instrument.

How to choose

Choose by voltage and range. Up to 1000 MΩ at 100, 250 and 500 V, take ES0202/1-G. Up to 10 000 MΩ at 2500 V, take ES0202/2-G. We will match version and kit to your task, so write to a USK ENERGY manager.

Request a price and lead time

Megaohmmeters ES0202/1-G and ES0202/2-G (ЭС0202, ЭСО202, ЭСО 202/2Г, ЭС 0202, ESO202, ES 0202/2G), with built-in hand generator, 100–2500 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Are ЭСО202 and ЭС0202 the same instrument?

Yes. The correct spelling is ЭС0202, with the digits 0202 after the letters. Variants such as ЭСО202, ESO202, ЭСО 202/2Г or ES 0202/2G are common, but they name the same megaohmmeter.

What voltage do ES0202/1-G and ES0202/2-G provide?

ES0202/1-G has three settings, 100, 250 and 500 V, with a scale up to 1000 MΩ. ES0202/2-G measures up to 10 000 MΩ at up to 2500 V.

Does the ES0202 need batteries or mains power?

No. A built-in electromechanical generator supplies power, and the handle turns at 120–144 rpm.

What is the error and operating temperature of ESO202?

Basic relative error is ±15 %, operating temperature from −30 to +50 °C.

How long can it measure without a break?

Operation is intermittent, one minute of measurement then two minutes of pause. Plan these pauses into long cable tests.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.