Modular GM10
Country: · Model: GM10
The GM10 is a modular SMARTDAC+ data logger assembled from the I/O modules you need. It supports 920 MHz wireless and Modbus, and monitoring and setting changes can be done over Bluetooth. Accuracy on a 60 mV signal is ±(0.01% of reading + 5 μV).
- Model
- Scan interval
- Multi-unit configuration
- 0 to 420
- Input type
- Measuring accuracy*1 (typical value*2)
- 60 mV
- ±(0.01% of reading +5 μV)
Technical specifications
| Model | Scan interval |
|---|---|
| Multi-unit configuration | 0 to 420 |
| Input type | Measuring accuracy*1 (typical value*2) |
| 60 mV | ±(0.01% of reading +5 μV) |
| 6 V (1-5 V) | ±(0.01% of reading + 2 mV) |
| B | ±1.5 °C |
| K (-200.0 to 1370.0 °C) | ±(0.01% of rdg +0.2 °C) for 0.0 to 1370.0 °C; ±(0.15% of rdg +0.2 °C) for -200.0 to 0.0 °C |
| K (-200.0 to 500.0 °C) | ±0.2 °C for 0.0 to 500.0 °C; ±(0.15% of rdg +0.2 °C) for -200.0 to 0.0 °C |
| J | ±0.2 °C for 0.0 to 1100.0 °C; ±(0.10% of rdg + 0.2 °C) for -200.0 to 0.0 °C |
| T | ±0.2 °C for 0.0 to 400.0 °C; ±(0.10% of rdg + 0.2 °C) for -200.0 to 0.0 °C |
| N | ±(0.01% of rdg + 0.2 °C) for 0.0 to 1300.0 °C; ±(0.22% of rdg + 0.2 °C) for -200.0 to 0.0 °C |
| Pt100 (-150.00 to 150.00 °C) | ±(0.02% of rdg + 0.16 °C) |
| Number of recording channels | Total sample time |
| 30 | Approx. 71 days |
| 100 | Approx. 23 days |
| 300 | Approx. 7 days |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The modular architecture lets you assemble just the channels the task needs rather than paying for extras. Besides I/O, the logger speaks many communication protocols, including 920 MHz wireless and Modbus. Monitoring and settings are available over Bluetooth, so a parameter can be changed without plugging in a cable. The unit supports FDA 21 CFR Part11 and AMS2750E/NADCAP, which matters in pharmaceutical and heat-treatment work. Accuracy for a 6 V (1 to 5 V) signal is ±(0.01% of reading + 2 mV), for a B thermocouple ±1.5 °C and for Pt100 ±(0.02% of reading + 0.16 °C). The multi-unit configuration is listed as 0 to 420.
How to choose
First decide the number of recording channels, because the archive time depends on it. According to the data, 30 channels give about 71 days of total sample time, 100 channels about 23 days and 300 channels about 7 days. Then pick input types from the accuracy table for thermocouples B, K, J, T, N and for Pt100. If you want a touch screen at the operator station, look at the touch-screen GP series recorders.
Request a price and lead time
Modular GM10. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How long can the GM10 record data?
Total sample time depends on the channel count. It is about 71 days for 30 channels, about 23 days for 100 and about 7 days for 300.
Does the GM10 have wireless communication?
Yes, 920 MHz wireless and Modbus are supported. Monitoring and setting changes are also possible over Bluetooth.
Does the GM10 meet FDA 21 CFR Part11?
The maker states support for FDA 21 CFR Part11 and AMS2750E/NADCAP. For an audit, check the settings against your process requirements.
What is the GM10 accuracy on a K thermocouple?
On the 0.0 to 1370.0 °C span accuracy is ±(0.01% of reading + 0.2 °C). For negative temperatures down to -200.0 °C the tolerance is ±(0.15% of reading + 0.2 °C).