Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

SAM3000 / SAM3001 modular multi-channel network analyzer (up to 32 three-phase circuits)

One modular SAM3000 / SAM3001 analyzer monitors up to 32 three-phase or 96 single-phase circuits and replaces dozens of separate panel analyzers or meters. It is installed in main distribution boards of buildings, data centres, shopping centres, industrial sites and street lighting, where consumption is broken down by outgoing lines.

Number of circuits
up to 32 three-phase or 96 single-phase
Current sensors
closed-core CTs, split-core CTs 100–600 A / 330 mV, 5 A / 330 mV adapter, Rogowski coils
Accuracy class, active energy
0.5S
Accuracy class, reactive energy
2

Technical specifications

Number of circuitsup to 32 three-phase or 96 single-phase
Current sensorsclosed-core CTs, split-core CTs 100–600 A / 330 mV, 5 A / 330 mV adapter, Rogowski coils
Accuracy class, active energy0.5S
Accuracy class, reactive energy2
Power qualityTHD and harmonics of U, I — class A; unbalance — class B
Supply24 V DC or 45–275 V AC/DC (power module); measuring modules self-powered
CommunicationRS485, Modbus RTU
Tariffsup to 4
Digital inputs/outputs2 DI, 1 DO (solid-state relay) — depending on the module
MountingDIN rail modules, IP20; remote display 96×96 mm, IP67

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The system is assembled on a DIN rail from an analyzer module, a power module, a communication module and a 96×96 mm remote display. The measuring modules are self-powered, and the power module is rated for 24 V DC in the SAM3000 or 45–275 V AC/DC in the SAM3001. The inputs take closed-core CTs, split-core transformers of 100–600 A with a 330 mV output, an adapter for existing CTs with a 5 A secondary, or Rogowski coils, for which there is a separate version. The accuracy class is 0.5S for active energy, 2 for reactive energy and 0.5 for apparent power, harmonics and THD of voltage and current are measured to class A, and unbalance to class B. The device meters reactive energy in four quadrants, keeps up to 4 tariffs, stores maximum, minimum and average values and gives a signal when a parameter goes out of limits. Data is transmitted over RS485 with Modbus RTU, and some modules have 2 digital inputs and a solid-state digital output. The analyzer and communication modules are IP20, the display is IP67, and the CE marking is confirmed by the declaration for AHM1/SAM3000.

How to choose

The set contents depend on the number of circuits and the type of existing current sensors, and the measuring modules 011, 012, M21, M22, M21A, M1A or M1B are selected for them. For a cabinet with a 24 V DC control supply the SAM3000 is taken, for a 45–275 V AC/DC supply the SAM3001 is needed, and for both a communication module SAM300_-02 and a display SAM300_-03 are added. A single incomer with an 8 MB archive is simpler to monitor with the panel AHM1, and reports under IEC 61000-4-30 class A are produced by the AQM2.

Request a price and lead time

SAM3000 / SAM3001 modular multi-channel network analyzer (up to 32 three-phase circuits). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many circuits can be connected to one SAM3000?

One set covers up to 32 three-phase or up to 96 single-phase circuits, and the required number of inputs is built up with measuring modules on the DIN rail.

Which current sensors suit the SAM3001?

Closed-core CTs, split-core CTs of 100–600 A with a 330 mV output, a 5 A / 330 mV adapter for already installed transformers, and Rogowski coils.

Does the SAM3000 meter by several tariffs?

Yes, the device supports up to 4 tariffs, counts reactive energy in four quadrants and stores maximum, minimum and average values for load analysis.

Where should the SAM3000 display and modules be placed in the board?

The 96×96 mm remote display with protection rating IP67 is brought out to the board door, and the analyzer and communication modules with IP20 are placed on the DIN rail inside the cabinet.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.