CIRWATT B (410D/T, 405, 502, 505) — multi-tariff recording meters for LV and MV metering points

Multi-tariff recording meters of the CIRWATT B series (410D/T, 405, 502, 505) are designed for commercial and technical metering at industrial and commercial sites and at connection points to the medium-voltage network. They record load profiles and have several communication options and expansion modules.

CIRWATT B410T
transformer connection; 3×230/400 or 3×63.5/110 V; .../5 or .../1 A; class B (MID, EN 50470) / 1 (IEC 62053-21), reactive — class 2; consumer type 3
CIRWATT B502
MV via VT and CT; 3×63.5/110 V; class 0.2S (IEC 62053-22) / reactive 0.5; consumer type 1 (> 10 MW)
CIRWATT B505, B405, B410D
other classes and connection schemes (including direct)
Quadrants
2 (consumption) or 4 (solar plants)

Technical specifications

CIRWATT B410Ttransformer connection; 3×230/400 or 3×63.5/110 V; .../5 or .../1 A; class B (MID, EN 50470) / 1 (IEC 62053-21), reactive — class 2; consumer type 3
CIRWATT B502MV via VT and CT; 3×63.5/110 V; class 0.2S (IEC 62053-22) / reactive 0.5; consumer type 1 (> 10 MW)
CIRWATT B505, B405, B410Dother classes and connection schemes (including direct)
Quadrants2 (consumption) or 4 (solar plants)
CommunicationRS-232, RS-485, Ethernet; expansion modules
Memorynon-volatile; events in serial flash; lithium battery > 20 years
Frequency50 / 60 Hz

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

B410T is a three-phase transformer-connected meter, class B for active energy per MID (EN 50470) or class 1 per IEC 62053-21, class 2 for reactive energy (IEC 62053-23). Versions are available for 3 × 230/400 V or 3 × 63.5/110 V, with current inputs .../5 A or .../1 A (maximum current 10 A), a frequency of 50 or 60 Hz, and its own consumption below 2 W / 10 VA. There are 2-quadrant versions for consumption and 4-quadrant versions for solar plants, where the meter counts generation as well. Communication is RS-232, RS-485 and Ethernet. Settings and events are stored in flash memory, data is held by non-volatile memory, and the lithium battery has a service life of over 20 years at 30 °C. The supply voltage is 80–115 % Un. Data is transmitted to SCADA energy management systems.

How to choose

The choice depends on the voltage level of the input and the accuracy class. B410T for 3 × 230/400 V suits shopping centres, enterprises and residential areas with high consumption (consumer type 3). B502 has class 0.2S for active energy (IEC 62053-22) and 0.5 for reactive, and is designed for medium-voltage inputs through VT and CT (3 × 63.5/110 V.../5 A) at sites above 10 MW (consumer type 1). For other classes and connection schemes there are B505, B405 and B410D. For DIN-rail metering up to 100 A consider CEM-D, and for network quality analysis CVM.

Request a price and lead time

CIRWATT B (410D/T, 405, 502, 505) — multi-tariff recording meters for LV and MV metering points. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What accuracy class does the CIRWATT B410T meter have?

Class B per MID (EN 50470) or 1 per IEC 62053-21 for active energy, class 2 for reactive.

What inputs is CIRWATT B502 designed for?

For medium-voltage inputs with external VT and CT, 3 × 63.5/110 V, at sites above 10 MW. Accuracy class 0.2S.

Can the meter be used for metering solar plant generation?

Yes, there are 4-quadrant versions for this, which record both generation and consumption.

What communication interfaces do CIRWATT B meters have?

RS-232, RS-485 and Ethernet, plus expansion modules for other channels.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.