Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

НПМ-15 — universal single-channel signal converter with display

accuracy ±0.2 % · output 0–5, 0–20, 4–20 mA, 0–10 V · supply 24 V DC / 230 V AC · measurement period 0.1 s

The НПМ-15 is a single-channel microprocessor-based signal converter with a universal input and a built-in 1-inch OLED display. It accepts signals from thermocouples (K, L, N, J, S, R, B, T, E, A-1, A-2, A-3), Pt100, Pt500 and Pt1000 resistance thermometers, standard current and voltage signals, and resistance up to 2500 Ohm. The measured value is converted into an analogue output of 0–5 mA, 0–20 mA, 4–20 mA or 0–10 V and is also transmitted digitally over RS-485 using Modbus RTU. Accuracy is ±0.2 % with a measurement period of 0.1 s. All electrical circuits are galvanically isolated (at least 500 V), and two discrete outputs are available as either transistor or relay types. Configuration is carried out via USB, with settings held in non-volatile memory. The DIN-rail housing is rated IP20 for operation from -40 °C to +70 °C. Typical use is in automation systems, passing sensor signals to PLCs, SCADA and HMI.

Number of channels
1
Current input signals
0–5 mA, 0–20 mA, 4–20 mA, -5…5 mA, -20…20 mA
Voltage input signals
0–10 V, 0–100 mV, -10…10 V, -100…100 mV
Resistance thermometers
Pt100, Pt500, Pt1000

Technical specifications

Number of channels1
Current input signals0–5 mA, 0–20 mA, 4–20 mA, -5…5 mA, -20…20 mA
Voltage input signals0–10 V, 0–100 mV, -10…10 V, -100…100 mV
Resistance thermometersPt100, Pt500, Pt1000
ThermocouplesK, L, N, J, S, R, B, T, E, A-1, A-2, A-3
Resistance input0–150 Ohm, 0–300 Ohm, 0–1200 Ohm, 0–2500 Ohm
Output signals0–5 mA, 0–20 mA, 4–20 mA, 0–10 V
Discrete outputs2: transistor up to 40 V, 100 mA or relay up to 230 V, 5 A
Supply voltage24 V DC, 230 V AC
Accuracy±0.2 %
Measurement period0.1 s
Galvanic isolation≥ 500 V
InterfacesUSB, RS-485
ProtocolModbus RTU
DisplayOLED, 1 inch
MountingDIN rail
Degree of protectionIP20
Operating temperature-40 °C to +70 °C
Dimensions110 × 23 × 115 mm
Weight0.2 kg
StandardsДСТУ IEC 60381-1, ДСТУ IEC 60381-2, ДСТУ ІЕС 60751, ДСТУ 2837-94, ДСТУ EN 60584-1, ДСТУ EN 60529:2014, ДСТУ IEC 60654-1:2001, ДСТУ IEC 60654-3:2001, ДСТУ EN 61326-1

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

When ordering, select the input signal code (01–31) to suit the sensor type: thermocouple, resistance thermometer, current, voltage or resistance. Then select the output signal code (01–05). Discrete outputs come as transistor (up to 40 V, 100 mA) for low-current circuits or relay (up to 230 V, 5 A) for switching loads. The supply voltage is either 24 V DC or 230 V AC.

Similar products

Test and measurement

Request a price and lead time

НПМ-15 — universal single-channel signal converter with display. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.