CVM-B100/B150, CVM-C10/C11, CVM-E3-MINI, CVM-D — panel and DIN-rail network analysers

The CVM series are fixed network analysers for LV and MV panels that work through measuring transformers. The formats range from 96 × 96 and 144 × 144 mm panel units to a 3-module DIN unit, plus a version for direct current up to 1500 V.

CVM-B100 / B150
96×96 / 144×144 mm; colour VGA; 5 voltage inputs up to 1000 V phase-to-phase; 4 current inputs (ITF); U, I class 0.2; energy 0.5S; up to 4 expansion modules; RS-485 Modbus/RTU, BACnet; IP65 front
CVM-C10 / C11
96×96 mm; harmonics up to the 31st; neutral current; 3 tariffs; 2 relays + 2 digital outputs; version with FLEX coils
CVM-E3-MINI
DIN rail 3 modules (72×72 adapter); 4 quadrants; harmonics up to the 31st; Ethernet / Wi-Fi Modbus TCP; ITF, MC .../250 mA, FLEX
CVM-D41 DC
DIN, 6 modules; DC up to 1500 V, shunt 50–600 mV; 2 relays, analogue output 4–20 mA; RS-485

Technical specifications

CVM-B100 / B15096×96 / 144×144 mm; colour VGA; 5 voltage inputs up to 1000 V phase-to-phase; 4 current inputs (ITF); U, I class 0.2; energy 0.5S; up to 4 expansion modules; RS-485 Modbus/RTU, BACnet; IP65 front
CVM-C10 / C1196×96 mm; harmonics up to the 31st; neutral current; 3 tariffs; 2 relays + 2 digital outputs; version with FLEX coils
CVM-E3-MINIDIN rail 3 modules (72×72 adapter); 4 quadrants; harmonics up to the 31st; Ethernet / Wi-Fi Modbus TCP; ITF, MC .../250 mA, FLEX
CVM-D41 DCDIN, 6 modules; DC up to 1500 V, shunt 50–600 mV; 2 relays, analogue output 4–20 mA; RS-485
Cir-SET 421/424recorder for substations: 8/16 variables, Ethernet, RS-232/485
CVM-B supply100–240 V AC / 120–300 V DC

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

CVM-B100 and B150 measure in four quadrants, that is, both consumption and generation, in 3-wire and 4-wire circuits. They have a colour VGA screen, 5 voltage inputs up to 1000 V between phases and 4 ITF current inputs for .../5 A.../1 A and .../0.250 A. The accuracy class is 0.2 for voltage and current and 0.5S for energy. The supply is 100–240 V AC / 120–300 V DC, the communication is RS-485 (Modbus/RTU, BACnet), with up to 4 expansion modules and an IP65 front. CVM-C10 and C11, 96 × 96 mm, count harmonics up to the 31st, neutral current and three tariffs, have 2 relays and 2 digital outputs, and the pulse output is tied to cost, CO₂ emissions or energy. CVM-E3-MINI takes 3 modules on a DIN rail (in a 72 × 72 mm panel with an adapter), has Ethernet and Wi-Fi with Modbus TCP, supports MC transformers .../250 mA and is configured through MyConfig.

How to choose

The choice is determined by the format and the network type. For a panel with a colour VGA screen take CVM-B100 or B150, for harmonics up to the 31st and tariffs CVM-C10 / C11, and for a DIN rail with Ethernet CVM-E3-MINI is suitable. DC networks up to 1500 V DC with a shunt of 50–600 mV are covered by CVM-D41 DC with 6 modules and an analogue output of 0/4–20 mA.

Request a price and lead time

CVM-B100/B150, CVM-C10/C11, CVM-E3-MINI, CVM-D — panel and DIN-rail network analysers. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What accuracy class do CVM-B100 and B150 analysers have?

Class 0.2 for voltage and current and 0.5S for energy. The ITF current inputs work with transformers .../5 A.../1 A and .../0.250 A.

Does CVM-C10 meter by tariffs?

Yes, by three tariffs, for example grid, generator and solar plant. For signalling there are 2 relays and 2 digital outputs.

How does CVM-D41 DC differ from CVM-B100?

It works on direct current up to 1500 V through a shunt of 50–600 mV. It has 2 digital inputs, 2 relays, an analogue output and RS-485 Modbus/RTU.

What supply do CVM-B analysers need?

Universal, 100–240 V AC or 120–300 V DC.

What is Cir-SET 421/424?

A recorder for substations with 8 or 16 variables, with Ethernet, RS-232 and RS-485.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.