Paramagnetic Oxygen Analyzer (Flameproof Type) MG8E

The MG8E paramagnetic oxygen analyzer in the flameproof Ex d IIBT4X version measures O2 from 0–1 to 0–25 vol%, with 3 programmable ranges. It works in flammable mixtures and at low oxygen concentrations, with ±1% span repeatability.

Measurement object
Oxygen concentration in gaseous mixture
Measurement system
Paramagnetic system
Measurement range
0-1 to 0-25 vol%O2, 3 ranges can be programmed.
Analog output signal
4 to 20 mA DC (load resistance: Max. 550 Ω)

Technical specifications

Measurement objectOxygen concentration in gaseous mixture
Measurement systemParamagnetic system
Measurement range0-1 to 0-25 vol%O2, 3 ranges can be programmed.
Analog output signal4 to 20 mA DC (load resistance: Max. 550 Ω)
Contact inputRemote range switching, calibration start
Sample Gas ConditionGas flow; 300 to 800 ml/min. ±10% of a set value (Standard 600 ml/min) Gas pressure; Approx. 7 kPa in Analyzer inlet Gas temperature; 0 to 50℃
Auxiliary GasN2 gas, Pressure; 350 to 500 kPa
Calibration MethodAutomatic calibration, Semiautomatic calibration, Manual calibration
Calibration gasZero gas; N2 gas Span gas; Dry air
Auxiliary gas pressureN2 gas, 350 to 500 kPa (Approx. 35 ml/min)
Ambient temperature-5 to 50℃
InstallationIndoor, panel or wall mounting
StructureFlameproof (Ex d IIBT4X)
Power supply90 to 127 V AC, 48 to 63 Hz, 50 or 60 Hz
Repeatability±1% or less of span
Linearity±1% or less of span
Response time90% response within 3 sec; measured by analog output signal change after gas is through the analyzer inlet.

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The principle is the same as in the MG8G, a magnet attracts oxygen, so flammable components of the mixture do not interfere. The differences lie in the lower range limit and the construction, as the Ex d IIBT4X enclosure permits installation in a hazardous area. The output is 4–20 mA DC into a load up to 550 Ω, and contact inputs switch the range and start calibration. Sample gas flows at 300–800 ml/min ±10% of the set value, standard 600 ml/min, at about 7 kPa at the inlet and 0–50 °C. Auxiliary N2 is needed at 350–500 kPa. Supply is 90–127 V AC, 48–63 Hz. Linearity and repeatability are ±1% of span and the 90% response takes 3 s.

How to choose

Take the MG8E when oxygen is scarce, since the scale starts at 0–1 vol%, or when the analyzer goes into an area that calls for a flameproof version. If a range from 0–5 vol% is enough and the area is ordinary, the MG8G will do. Pick the working flow within 300–800 ml/min, and keep condensate out of the sample gas.

Request a price and lead time

Paramagnetic Oxygen Analyzer (Flameproof Type) MG8E. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the lowest range of the MG8E?

The O2 measurement range runs from 0–1 to 0–25 vol%, and 3 ranges can be programmed.

What explosion protection does the MG8E have?

The enclosure is Ex d IIBT4X, a flameproof type, so the analyzer can be installed in a hazardous area.

What auxiliary N2 pressure is required?

350–500 kPa, with a flow of about 35 ml/min.

What ambient temperature is allowed?

From -5 to 50 °C, and the instrument is mounted indoors on a panel or a wall.

What sample gas flow does the MG8E need?

300–800 ml/min ±10% of the set value, standard 600 ml/min, at about 7 kPa at the inlet.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.