UnoIQ and DuoIQ — Compact Single- and Dual-Gas Detectors with Replaceable Sensor Modules
Country: United Kingdom · Model: UnoIQ / DuoIQ
Personal gas detectors with replaceable pre-calibrated sensor modules, UnoIQ for one gas and DuoIQ for two. The case is 96×55×32 mm, the weight 134 and 140 g, protection IP66 and IP68, and it withstands a drop from 6 m. Intrinsically safe version Ex ia IIC T4 Ga.
- UnoIQ
- 1 gas; 134.2 g
- DuoIQ
- 2 gases; 139.8 g
- Dimensions
- 96×55×32 mm (standard module), 106×55×32 mm (deep module)
- Sensors
- toxic, O2, IR, pellistor — pre-calibrated replaceable modules
Technical specifications
| UnoIQ | 1 gas; 134.2 g |
|---|---|
| DuoIQ | 2 gases; 139.8 g |
| Dimensions | 96×55×32 mm (standard module), 106×55×32 mm (deep module) |
| Sensors | toxic, O2, IR, pellistor — pre-calibrated replaceable modules |
| T90 | < 10 s (depending on the sensor) |
| UnoIQ battery | toxic/O2 — 10 days continuous (31 days at 8 h each); IR — 1 day; pellistor — 1 day |
| DuoIQ battery | tox/O2 + tox — 7 days (20 days at 8 h each); with IR — 1 day; with pellistor — 1 day |
| Charging | 0–80 % in 2 h, 0–100 % < 3 h |
| Durability / protection | 6 m drop; IP66 and IP68 |
| Explosion protection | ATEX II 1G Ex ia IIC T4 Ga; CSA Class I Div 1 |
| Connectivity | Bluetooth, Connect |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The user replaces the sensor module on their own, without contacting the manufacturer, and so reconfigures the instrument for another gas, which reduces downtime. Electrochemical toxic and oxygen sensors are supported, as well as infrared and pellistor sensors for flammable gases. The deep module increases the length to 106×55×32 mm. The T90 response time is less than 10 seconds depending on the sensor. The alarm is visual, vibrating and audible at 95 dB with low and high thresholds, TWA and STEL, and a log of up to 500 events. The operating temperature is from −20 to +55 °C, humidity 0–95 %. Via Bluetooth the instruments connect to the cloud service Connect for compliance monitoring and fleet management, and servicing is done at the IQhub station. Explosion protection ATEX II 1G Ex ia IIC T4 Ga and CSA Class I Division 1. Charging to 80 % takes 2 hours, a full charge less than 3 hours.
How to choose
For one gas take UnoIQ, which can later be upgraded to a dual-gas version. For two gases choose DuoIQ right away. The sensor type determines the runtime. UnoIQ with a toxic or oxygen sensor runs 10 days continuously (31 days on 8-hour shifts), with an infrared or pellistor sensor about 1 day. DuoIQ with toxic and oxygen sensors runs 7 days (20 days at 8 hours each). For four gases in one case see Tetra 3.
Request a price and lead time
UnoIQ and DuoIQ — Compact Single- and Dual-Gas Detectors with Replaceable Sensor Modules. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How does UnoIQ differ from DuoIQ?
UnoIQ monitors one gas and weighs 134.2 g, DuoIQ monitors two gases and weighs 139.8 g.
How to change the gas in UnoIQ or DuoIQ?
Replace the pre-calibrated sensor module on a plug-and-play basis without the manufacturer.
How long does the battery last?
UnoIQ with a toxic or O2 sensor 10 days continuously, DuoIQ 7 days. With an IR or pellistor sensor about 1 day.
What protection and explosion protection do the instruments have?
IP66 and IP68, they withstand a drop from 6 m. Explosion protection ATEX II 1G Ex ia IIC T4 Ga and CSA Class I Division 1.
How long does charging take?
To 80 % in 2 hours, fully in less than 3 hours.