ПНС-420 — AC voltage to 4–20 mA converter
Country: Ukraine · Model: ПНС-420
input 0–10 … 0–500 V AC · output 4…20 mA (passive) · accuracy 0.4 % · supply 18–36 V DC
The ПНС-420 is a measuring transducer that linearly converts single-phase AC voltage into a standardised 4…20 mA current signal. The output is passive: the unit draws its power from the current loop itself at 18–36 V DC, so no separate supply is required. The input circuits are fully galvanically isolated from the output (isolation of at least 2000 V). Seven versions are available, with input ranges from 0–10 V up to 0–500 V. Conversion accuracy is 0.4 %. The 26 mm wide housing (76 × 26 × 115 mm, weight 0.13 kg) mounts on a 35 mm DIN rail and is rated IP20. The operating temperature range is −40 to +70 °C. The converter is used for monitoring the voltage of electrical networks, in telemechanics systems and in the automation of power facilities and metallurgical plants. It also suits industrial automation and measurement systems where a voltage signal must be passed to a controller or recorder.
- Input signal
- AC voltage: 0–10 V, 0–15 V, 0–60 V, 0–100 V, 0–150 V, 0–250 V, 0–500 V
- Output signal
- 4…20 mA (passive)
- Supply voltage
- 18–36 V DC (loop-powered)
- Accuracy
- 0.4 %
Technical specifications
| Input signal | AC voltage: 0–10 V, 0–15 V, 0–60 V, 0–100 V, 0–150 V, 0–250 V, 0–500 V |
|---|---|
| Output signal | 4…20 mA (passive) |
| Supply voltage | 18–36 V DC (loop-powered) |
| Accuracy | 0.4 % |
| Galvanic isolation | full, at least 2000 V |
| Mounting | 35 mm DIN rail |
| Degree of protection | IP20 |
| Operating temperature | −40…+70 °C |
| Dimensions | 76 × 26 × 115 mm |
| Weight | 0.13 kg |
| ПНС-420-01 | input 0–10 V |
| ПНС-420-02 | input 0–15 V |
| ПНС-420-03 | input 0–60 V |
| ПНС-420-04 | input 0–100 V |
| ПНС-420-05 | input 0–150 V |
| ПНС-420-06 | input 0–250 V |
| ПНС-420-07 | input 0–500 V |
| Standards | ГОСТ 22261, ГОСТ 15150-69, ГОСТ 26828, ГОСТ 12971, ГОСТ 23170, ГОСТ 9.014, ГОСТ 7376, ГОСТ 10354, ГОСТ 5244, EN50022 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Choose the version by the highest voltage to be measured: ПНС-420-01 for 0–10 V, -02 for 0–15 V, -03 for 0–60 V, -04 for 0–100 V, -05 for 0–150 V, -06 for 0–250 V (typical for single-phase mains) and -07 for 0–500 V. The range should cover the maximum expected voltage with a small margin.
Similar products
Request a price and lead time
ПНС-420 — AC voltage to 4–20 mA converter. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.