MYeBOX 150 / 1500 — portable power quality analysers (class A)

MYeBOX 150 and MYeBOX 1500 are portable class A power quality analysers with 4 voltage inputs and 4 current inputs. They record parameters per EN 50160, as well as transients and waveforms. The device is configured from a phone or through the web, so it is convenient to take along for energy audits and for finding the causes of failures.

Models
MYeBOX 150, MYeBOX 1500 (including 4G)
Inputs
4 voltages (U1–U3, Un), 4 currents (I1–I3, In)
Voltage
10–600 V~ phase-to-neutral, CAT III 600 V; frequency 42.5–69 Hz
Current
clamps and flexible sensors 100/1000/10 000 A (output 0.250 A or 0.333 V)

Technical specifications

ModelsMYeBOX 150, MYeBOX 1500 (including 4G)
Inputs4 voltages (U1–U3, Un), 4 currents (I1–I3, In)
Voltage10–600 V~ phase-to-neutral, CAT III 600 V; frequency 42.5–69 Hz
Currentclamps and flexible sensors 100/1000/10 000 A (output 0.250 A or 0.333 V)
AccuracyU, I class 0.2; P 0.5; Q 1 (IEC 61557-12); kWh 0.5S; frequency — class A (IEC 61000-4-30)
Qualityharmonics up to the 50th (IEC 61000-4-7), flicker (IEC 61000-4-15), unbalance, events and transients with waveforms
CommunicationWi-Fi; app/web, MYeBOX Cloud; micro-USB
Supply100–240 V AC; Li battery 3700 mAh, 2 h runtime
Recordingperiods from 1 s to 1 day, FAT32

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The analyser works in single-, two- and three-phase networks with and without a neutral, and has voltage inputs (U1, U2, U3, Un) and current inputs (I1, I2, I3, In). It measures true RMS values, meters consumption and generation in 4 quadrants and compiles a log of voltage quality events per EN 61000-4-30. For each recording period, waveforms are saved, as well as the waveform linked to an event. The voltage range is 10–600 V~ phase-to-neutral (CAT III 600 V), and the frequency is 42.5–69 Hz. The current sensors have an output of 0.250 A or 0.333 V for 100, 1000 and 10 000 A, for example FLEX-R45 flexible coils, with an operating range of 1–200 % In. Voltage and current have class 0.2, active and apparent power 0.5, reactive power level 1 per IEC 61557-12, and active energy 0.5S per IEC 62053-22. Harmonics and THD are evaluated up to the 50th per IEC 61000-4-7, and Pst flicker with a 5 % error per IEC 61000-4-15. Recording is done with a period from 1 s to 1 day, and the file system is FAT32. The 3700 mAh battery runs for 2 h and charges in 6 h.

How to choose

Models 150 and 1500 share the same measurement base, so compare them by the type of communication. The 4G versions give remote access without a local network, while the others use Wi-Fi. The choice of current sensors depends on the current magnitude, because the 100, 1000 and 10 000 A ranges cover lines from cabinets to substation busbars. For permanent metering at the incomer it is better to take a DIN-rail meter, for example CEM-D, and keep the MYeBOX for field measurements.

Request a price and lead time

MYeBOX 150 / 1500 — portable power quality analysers (class A). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What accuracy class do MYeBOX 150 and 1500 analysers have?

Voltage and current have class 0.2, active and apparent power 0.5, reactive power 1 per IEC 61557-12. Frequency corresponds to class A per IEC 61000-4-30.

What current sensors can be connected to MYeBOX?

Clamps and flexible coils, for example FLEX-R45, for 100, 1000 and 10 000 A with an output of 0.250 A or 0.333 V. The measuring range is 1–200 % In.

How long does MYeBOX run without the mains?

Up to 2 h from the built-in 3700 mAh lithium battery. Charging takes 6 h, and the adapter is supplied from 100–240 V AC.

Up to which harmonic does the analyser evaluate distortion?

Up to the 50th per IEC 61000-4-7, class 1. Pst flicker is measured per IEC 61000-4-15, and unbalance corresponds to class A.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.