CP300_ / CP400_ / CP40 / ATIP / ATUP / ATICAP / ATUCAP / ATS1P / ATS2P programmable measuring transducers with RS485 and USB
Country: Spain · Model: CP300_ / CP400_ / CP40 / ATIP / ATUP / ATICAP / ATUCAP / ATS1P / ATS2P
The programmable measuring transducers CP300_, CP400_, CP40, ATIP, ATUP, ATICAP, ATUCAP, ATS1P and ATS2P have analog outputs and digital RS485 and USB interfaces. One device feeds a signal to a PLC or telemetry unit and sends data over Modbus to a dispatch system, and the ranges are changed in software, without replacement.
- CP300_ / CP400_
- multifunction three-phase: 3–4 analog outputs, 2 relay outputs (energy pulses/alarm); input x/5–x/1 A, 100–440 V; supply 85–264 V AC / 90–300 V DC or 18–72 V DC
- CP40
- up to 2, 3 or 4 analog outputs; RMS current 1/5 A, voltage 3×63.5/100 V; USB and RS485 simultaneously; programmable zero, full scale, broken-line characteristic
- ATIP / ATUP
- microprocessor-based current / voltage transducers; supply 40–275 V AC/DC; consumption 1.37–2.2 VA; RS485 (9600 baud) and USB
- ATICAP / ATUCAP
- DC current from shunt / DC voltage; adjustable shunt rating; RS485, USB
Technical specifications
| CP300_ / CP400_ | multifunction three-phase: 3–4 analog outputs, 2 relay outputs (energy pulses/alarm); input x/5–x/1 A, 100–440 V; supply 85–264 V AC / 90–300 V DC or 18–72 V DC |
|---|---|
| CP40 | up to 2, 3 or 4 analog outputs; RMS current 1/5 A, voltage 3×63.5/100 V; USB and RS485 simultaneously; programmable zero, full scale, broken-line characteristic |
| ATIP / ATUP | microprocessor-based current / voltage transducers; supply 40–275 V AC/DC; consumption 1.37–2.2 VA; RS485 (9600 baud) and USB |
| ATICAP / ATUCAP | DC current from shunt / DC voltage; adjustable shunt rating; RS485, USB |
| ATS1P / ATS2P | temperature from Pt100/Pt1000 / resistance of OLTC position sensor; output 4–20 mA, 0–5 mA, 0–10 V |
| Output isolation | from input, supply and serial port |
| Protocol | Modbus |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
CP300_ and CP400_ are multifunction three-phase transducers with a current input of x/5 or x/1 A and a voltage input of 100, 110, 230, 400 or 440 V. They measure phase and line voltages, currents by true RMS value, and powers per phase and in total. Three or four analog outputs and two contact outputs are configured as energy pulses, alarm or programmable contacts, with a supply of 85–264 V AC / 90–300 V DC or 18–72 V DC. CP40 is more compact, has 2, 3 or 4 analog outputs, USB and RS485 at the same time, RMS current of 1 or 5 A and voltage of 3×63.5/100 V AC, and for the outputs you set zero, full scale and a broken-line characteristic. ATIP (current) and ATUP (voltage) measure one quantity, and have RS485 (9600 baud), USB, a 40–275 V AC/DC supply and a consumption of 1.37–2.2 VA. ATICAP converts the DC voltage from a shunt into an isolated current or voltage, and ATUCAP does the same for DC voltage. ATS1P measures temperature from Pt100 or Pt1000, and ATS2P the resistance of an OLTC position sensor, with outputs of 4–20 mA, 0–5 mA or 0–10 V.
How to choose
For a board with a three-phase input take CP300_ or CP400_, and when a smaller housing is needed, CP40. A single quantity, current or voltage, is converted by ATIP and ATUP, and DC voltage from a shunt by ATICAP. The temperature and OLTC position of a power transformer are monitored by ATS1P and ATS2P. For power quality analysis look at AQM2 and SAM3000 or SAM3001.
Request a price and lead time
CP300_ / CP400_ / CP40 / ATIP / ATUP / ATICAP / ATUCAP / ATS1P / ATS2P programmable measuring transducers with RS485 and USB. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What inputs and supply does CP300_ have?
Current x/5 or x/1 A, voltage 100, 110, 230, 400 or 440 V. Supply 85–264 V AC / 90–300 V DC or 18–72 V DC.
Can USB and RS485 be used at the same time?
In CP40 yes, both ports work at the same time. Configuration is through software, with the Modbus protocol.
What output signals do ATS1P and ATS2P have?
4–20 mA, 0–5 mA or 0–10 V. ATS1P measures the temperature of Pt100 or Pt1000 sensors, and ATS2P the resistance of the OLTC position sensor.
What are the supply and consumption of ATIP and ATUP?
Supply 40–275 V AC/DC, consumption 1.37–2.2 VA, default RS485 speed 9600 baud. CE declarations are available for CP4003 and ATIP-ATUP.