CP300_ / CP400_ / CP40 / ATIP / ATUP / ATICAP / ATUCAP / ATS1P / ATS2P programmable measuring transducers with RS485 and USB

The programmable measuring transducers CP300_, CP400_, CP40, ATIP, ATUP, ATICAP, ATUCAP, ATS1P and ATS2P have analog outputs and digital RS485 and USB interfaces. One device feeds a signal to a PLC or telemetry unit and sends data over Modbus to a dispatch system, and the ranges are changed in software, without replacement.

CP300_ / CP400_
multifunction three-phase: 3–4 analog outputs, 2 relay outputs (energy pulses/alarm); input x/5–x/1 A, 100–440 V; supply 85–264 V AC / 90–300 V DC or 18–72 V DC
CP40
up to 2, 3 or 4 analog outputs; RMS current 1/5 A, voltage 3×63.5/100 V; USB and RS485 simultaneously; programmable zero, full scale, broken-line characteristic
ATIP / ATUP
microprocessor-based current / voltage transducers; supply 40–275 V AC/DC; consumption 1.37–2.2 VA; RS485 (9600 baud) and USB
ATICAP / ATUCAP
DC current from shunt / DC voltage; adjustable shunt rating; RS485, USB

Technical specifications

CP300_ / CP400_multifunction three-phase: 3–4 analog outputs, 2 relay outputs (energy pulses/alarm); input x/5–x/1 A, 100–440 V; supply 85–264 V AC / 90–300 V DC or 18–72 V DC
CP40up to 2, 3 or 4 analog outputs; RMS current 1/5 A, voltage 3×63.5/100 V; USB and RS485 simultaneously; programmable zero, full scale, broken-line characteristic
ATIP / ATUPmicroprocessor-based current / voltage transducers; supply 40–275 V AC/DC; consumption 1.37–2.2 VA; RS485 (9600 baud) and USB
ATICAP / ATUCAPDC current from shunt / DC voltage; adjustable shunt rating; RS485, USB
ATS1P / ATS2Ptemperature from Pt100/Pt1000 / resistance of OLTC position sensor; output 4–20 mA, 0–5 mA, 0–10 V
Output isolationfrom input, supply and serial port
ProtocolModbus

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

CP300_ and CP400_ are multifunction three-phase transducers with a current input of x/5 or x/1 A and a voltage input of 100, 110, 230, 400 or 440 V. They measure phase and line voltages, currents by true RMS value, and powers per phase and in total. Three or four analog outputs and two contact outputs are configured as energy pulses, alarm or programmable contacts, with a supply of 85–264 V AC / 90–300 V DC or 18–72 V DC. CP40 is more compact, has 2, 3 or 4 analog outputs, USB and RS485 at the same time, RMS current of 1 or 5 A and voltage of 3×63.5/100 V AC, and for the outputs you set zero, full scale and a broken-line characteristic. ATIP (current) and ATUP (voltage) measure one quantity, and have RS485 (9600 baud), USB, a 40–275 V AC/DC supply and a consumption of 1.37–2.2 VA. ATICAP converts the DC voltage from a shunt into an isolated current or voltage, and ATUCAP does the same for DC voltage. ATS1P measures temperature from Pt100 or Pt1000, and ATS2P the resistance of an OLTC position sensor, with outputs of 4–20 mA, 0–5 mA or 0–10 V.

How to choose

For a board with a three-phase input take CP300_ or CP400_, and when a smaller housing is needed, CP40. A single quantity, current or voltage, is converted by ATIP and ATUP, and DC voltage from a shunt by ATICAP. The temperature and OLTC position of a power transformer are monitored by ATS1P and ATS2P. For power quality analysis look at AQM2 and SAM3000 or SAM3001.

Request a price and lead time

CP300_ / CP400_ / CP40 / ATIP / ATUP / ATICAP / ATUCAP / ATS1P / ATS2P programmable measuring transducers with RS485 and USB. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What inputs and supply does CP300_ have?

Current x/5 or x/1 A, voltage 100, 110, 230, 400 or 440 V. Supply 85–264 V AC / 90–300 V DC or 18–72 V DC.

Can USB and RS485 be used at the same time?

In CP40 yes, both ports work at the same time. Configuration is through software, with the Modbus protocol.

What output signals do ATS1P and ATS2P have?

4–20 mA, 0–5 mA or 0–10 V. ATS1P measures the temperature of Pt100 or Pt1000 sensors, and ATS2P the resistance of the OLTC position sensor.

What are the supply and consumption of ATIP and ATUP?

Supply 40–275 V AC/DC, consumption 1.37–2.2 VA, default RS485 speed 9600 baud. CE declarations are available for CP4003 and ATIP-ATUP.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.