Р5018/5М — resistance box for loading instrument transformers during verification
Country: Ukraine · Model: Р5018/5М
working current 0.5–6 A · frequency 50 Hz · secondary load 1.25–50 VA · cos φ 0.8; 1
The Р5018/5М is a resistance box that acts as the secondary-circuit burden of an instrument transformer during verification in 50 Hz AC circuits. It provides a stepped series of nominal secondary load values S, expressed in volt-amperes, at a nominal power factor of either 0.8 or 1. The box's impedance has active and reactive components. Their nominal values in ohms and the limits of permissible intrinsic error in per cent are derived from calculation formulas. The working current range is 0.5–6 A. At cos φ 0.8 there are 14 load steps from 1.25 to 50 VA. At cos φ 1 there are six steps from 2.5 to 15 VA. Overall dimensions do not exceed 170 x 225 x 390 mm, and the weight is no more than 7.0 kg. The box is intended for laboratories and metrology departments that carry out verification of instrument transformers.
- Purpose
- load for instrument transformers during verification
- Working current range
- 0.5–6 A
- Reference frequency
- 50 Hz
- Nominal power factor (cos φ)
- 0.8; 1
Technical specifications
| Purpose | load for instrument transformers during verification |
|---|---|
| Working current range | 0.5–6 A |
| Reference frequency | 50 Hz |
| Nominal power factor (cos φ) | 0.8; 1 |
| Nominal secondary load S at cos φ 0.8 | 1.25; 2.5; 3.75; 5; 6.25; 7.5; 10; 12.5; 15; 20; 25; 30; 40; 50 VA |
| Nominal secondary load S at cos φ 1 | 2.5; 3.75; 5; 7.5; 10; 15 VA |
| Overall dimensions | max. 170 x 225 x 390 mm |
| Weight | max. 7.0 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
The load setting depends on the verification mode. At cos φ 0.8 the box covers the full series from 1.25 to 50 VA (14 values). At cos φ 1 only 2.5, 3.75, 5, 7.5, 10 and 15 VA are available. The current in the circuit under test must stay within 0.5–6 A.
Similar products
Request a price and lead time
Р5018/5М — resistance box for loading instrument transformers during verification. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.