Р5083 — automatic AC bridge for measuring C, L, R, tan δ and tan φ
Country: Ukraine · Model: Р5083
C: 1·10⁻¹⁶ – 10 F · L: 1·10⁻¹⁰ – 1·10⁷ H · R: 1·10⁻⁵ – 1·10¹⁰ Ω · 0.1–100 kHz
The Р5083 is a self-contained AC bridge for general industrial use. It automatically measures capacitance C, inductance L, active resistance R, loss tangent tan δ (Q factor QR) and phase-shift tangent tan φ (Q factors QC and QL). It also calculates the percentage deviation of a measured parameter from a set value. Results are shown digitally. The bridge operates at frequencies from 0.1 to 100 kHz. It covers capacitance from 1·10⁻¹⁶ to 10 F, inductance from 1·10⁻¹⁰ to 1·10⁷ H and resistance from 1·10⁻⁵ to 1·10¹⁰ Ω. At 1 kHz and above, a single measurement takes no more than 0.7 s; between 0.1 and 1 kHz it takes no more than 4 s. The instrument runs from a 220 V or 110 V, 50 Hz mains supply and draws no more than 100 V·A. Typical uses include scientific research, metrological certification of measuring instruments and quality control of electrical and radio components. With suitable transducers, it can also measure non-electrical quantities.
- Capacitance range C
- 1·10⁻¹⁶ – 10 F
- Inductance range L
- 1·10⁻¹⁰ – 1·10⁷ H
- Active resistance range R
- 1·10⁻⁵ – 1·10¹⁰ Ω
- Loss tangent tan δ (QR)
- 1·10⁻⁵ – 65535
Technical specifications
| Capacitance range C | 1·10⁻¹⁶ – 10 F |
|---|---|
| Inductance range L | 1·10⁻¹⁰ – 1·10⁷ H |
| Active resistance range R | 1·10⁻⁵ – 1·10¹⁰ Ω |
| Loss tangent tan δ (QR) | 1·10⁻⁵ – 65535 |
| Phase-shift tangent tan φ (QC, QL) | ±(1·10⁻⁵ – 65535) |
| Operating frequency range | 0.1–100 kHz |
| Measurement time at 1 kHz and above | max. 0.7 s |
| Measurement time at 0.1–1 kHz | max. 4 s |
| Result display | digital |
| Supply voltage | (220 ± 22) V or (110 ± 11) V |
| Supply frequency | (50 ± 1) Hz |
| Power consumption | max. 100 V·A |
| Dimensions | 440 × 158 × 405 mm |
| Weight | max. 16 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
The measuring range depends on the selected frequency and the voltage applied to the test object. The smallest capacitances (from 1·10⁻¹⁶ F) and inductances (from 1·10⁻¹⁰ H) are measured at 1.00–9.99 kHz. The largest values, up to 10 F and 1·10⁷ H, are available at 0.100–0.899 kHz. When the object voltage is reduced tenfold (UZ MIN), the limits narrow. The bridge can be powered from 220 V or 110 V mains.
Similar products
Request a price and lead time
Р5083 — automatic AC bridge for measuring C, L, R, tan δ and tan φ. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.