Р5101–Р5115 — single-value inductance standards
Country: Ukraine · Model: Р5101–Р5115
0.08–100 kHz · normal frequency (1 ± 0.1) kHz · accuracy classes 0.02–2 · up to 170×170×205 mm
The Р5101–Р5115 series comprises single-value inductance standards that act as reference elements in AC measurement circuits. Each unit reproduces one fixed inductance value. That value is certified at a set of check frequencies, so the standard can serve as a reference quantity during verification and calibration work. The operating frequency range is 0.08 to 100 kHz, with a normal frequency of (1 ± 0.1) kHz. Accuracy classes across the series run from 2 down to 0.02. The error in determining the inductance is specified as a fraction of the class K at 1 kHz, at 0.5–10 kHz and at 0.08, 50 and 100 kHz. Overall dimensions do not exceed 170×170×205 mm, and weight ranges from 3.5 to 4.5 kg depending on the model. Typical applications are laboratory AC measurement circuits, including bridges and comparators, checking inductance meters and calibrating measurement systems.
- Type
- single-value inductance standard
- Frequency range
- 0.08–100 kHz
- Normal frequency
- (1 ± 0.1) kHz
- Accuracy class Р5101
- 2
Technical specifications
| Type | single-value inductance standard |
|---|---|
| Frequency range | 0.08–100 kHz |
| Normal frequency | (1 ± 0.1) kHz |
| Accuracy class Р5101 | 2 |
| Accuracy class Р5102 | 1 |
| Accuracy class Р5103 | 0.2 |
| Accuracy class Р5104 | 0.1 |
| Accuracy class Р5105, Р5106 | 0.05 |
| Accuracy class Р5107–Р5115 | 0.02 |
| Error at 1 kHz, % of nominal | Р5101, Р5102 — 0.20·K; Р5103, Р5104 — 0.33·K; Р5105–Р5115 — 0.50·K |
| Error at 0.5, 1.5, 2.5, 5, 10 kHz, % of nominal | Р5101–Р5104 — 0.5·K; Р5105, Р5106 — 1.0·K; Р5107–Р5115 — 2.0·K |
| Error at 0.08, 50, 100 kHz, % of nominal | Р5101, Р5102 — 0.5·K; Р5103 — 1.0·K; Р5104, Р5105 — 2.0·K; Р5106 — not specified; Р5107–Р5115 — 0.5·K |
| Overall dimensions, max | 170×170×205 mm |
| Weight Р5101, Р5102, max | 3.5 kg |
| Weight Р5103–Р5114, max | 4.0 kg |
| Weight Р5115, max | 4.5 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Select the model by the required accuracy class: Р5101 is class 2, Р5102 class 1, Р5103 class 0.2, Р5104 class 0.1, Р5105 and Р5106 class 0.05, and Р5107–Р5115 class 0.02. If you need class 0.05 with a specified error at 0.08, 50 and 100 kHz, choose Р5105, as Р5106 has no specified error at these frequencies.
Similar products
Request a price and lead time
Р5101–Р5115 — single-value inductance standards. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.