Р596 — standard inductance measure
Country: Ukraine · Model: Р596
1 мкГ – 1 Г · accuracy classes 0.05–5 · 0.08–100 kHz · current up to 1000 мА
The Р596 is a standard inductance measure. It serves as a reference during verification or as an element of AC measuring circuits operating from 0.08 to 100 kHz. Nominal values cover 1 мкГ to 1 Г. Accuracy classes range from 0.05 to 5, depending on the nominal value. The unit is shielded and its winding is astatic. This practically eliminates the influence of external electromagnetic fields, so the value stays stable when the measure is placed near other equipment. The limit of basic error, expressed as a percentage of the nominal value, equals the accuracy class. This applies at 1 ± 0.01 kHz, humidity of no more than 80% and an ambient temperature of 20 ±5 °C for 1–50 мкГ measures or 20 ±2 °C for the others. Maximum current reaches 1000 мА. Overall dimensions are no more than 180 х 160 х 240 мм and weight no more than 6 кг. The measure is used for verification work in industrial and research laboratories and in calibration laboratories. It is intended for closed, heated rooms at 10–35 °C.
- Nominal inductance values
- 1 мкГ – 1 Г
- Accuracy classes
- 0.05 – 5
- Certification frequency
- 0.08 – 100 kHz
- Maximum current
- up to 1000 мА
Technical specifications
| Nominal inductance values | 1 мкГ – 1 Г |
|---|---|
| Accuracy classes | 0.05 – 5 |
| Certification frequency | 0.08 – 100 kHz |
| Maximum current | up to 1000 мА |
| Design | shielded, astatic winding |
| Reference conditions for basic error | 20 ±5 °C (1–50 мкГ), 20 ±2 °C (others); humidity ≤ 80%; 1 ± 0.01 kHz |
| Operating temperature | 10 – 35 °C |
| Relative humidity | up to 80% (at 20 °C) |
| Overall dimensions | max. 180 х 160 х 240 мм |
| Weight | max. 6 кг |
| Scope of supply | measure, technical description and operating manual, passport |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Select the nominal value to suit the instrument or circuit under test. The accuracy class depends on the value: 1 мкГ — 5; 2–10 мкГ — 1; 20–30 мкГ — 0.5; 50 мкГ — 0.2; 100–500 мкГ — 0.1; 1 мГ – 1 Г — 0.05. For low-frequency work from 0.08 kHz, choose the 100 мГ – 1 Г measures. Small values are certified at frequencies up to 100 kHz.
Similar products
Request a price and lead time
Р596 — standard inductance measure. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.