Р597 — standard capacitance measures, set of 19 (1 pF – 1.0 µF)

1 pF – 1.0 µF · accuracy classes 0.05; 0.1; 0.2 · 40–100000 Hz · up to 100 V

Р597 is a set of 19 standard capacitance measures with nominal values from 1 pF to 1.0 µF. The measures provide a reference capacitance or serve as elements of AC measuring circuits. The set includes two multi-value measures (Р597/1 with 1, 2, 3 and 4 pF, and Р597/2 with 10, 20, 30 and 40 pF) and single-value measures Р597/3 to Р597/19. Measures Р597/1 to Р597/10 operate from 40 to 100000 Hz at up to 100 V, with a loss tangent not exceeding 5·10⁻⁵. Measures Р597/11 to Р597/19 (0.01 to 1.0 µF) are rated for 40 to 10000 Hz and up to 20 V, with tan δ not exceeding 1·10⁻³. The accuracy class is 0.2, 0.05 or 0.1, depending on the measure. In a three-terminal connection, the initial capacitance of the multi-value measures does not exceed 0.03 pF. The set is used in measurement laboratories to verify and calibrate capacitance meters and to analyse AC circuits.

Number of measures in set
19
Nominal capacitance range
1 pF – 1.0 µF
Р597/1 (multi-value)
1, 2, 3, 4 pF; class 0.2
Р597/2 (multi-value)
10, 20, 30, 40 pF; class 0.05

Technical specifications

Number of measures in set19
Nominal capacitance range1 pF – 1.0 µF
Р597/1 (multi-value)1, 2, 3, 4 pF; class 0.2
Р597/2 (multi-value)10, 20, 30, 40 pF; class 0.05
Р597/3 – Р597/10 (single-value)100, 200, 300, 400, 1000, 2000, 3000, 4000 pF; class 0.05
Р597/11 – Р597/19 (single-value)0.01; 0.02; 0.03; 0.04; 0.1; 0.2; 0.3; 0.4; 1.0 µF; class 0.1
Basic error limits0.2 % (Р597/1); 0.05 % (Р597/2–Р597/10); 0.1 % (Р597/11–Р597/19)
Operating frequency range40–100000 Hz (Р597/1–Р597/10); 40–10000 Hz (Р597/11–Р597/19)
Maximum operating voltage100 V (Р597/1–Р597/10); 20 V (Р597/11–Р597/19)
Loss tangent, max5·10⁻⁵ (Р597/1–Р597/10); 1·10⁻³ (Р597/11–Р597/19)
tan δ measurement error, max5·10⁻⁵ (Р597/1–Р597/10); 5·10⁻⁴ (Р597/11–Р597/19)
Initial capacitance of Р597/1, Р597/2 (three-terminal connection)max 0.03 pF
Dimensions and weight, Р597/1–Р597/6, Р597/18, Р597/19height 165 mm, diameter 180 mm, 5 kg
Dimensions and weight, Р597/7–Р597/10height 260 mm, 11 kg
Dimensions and weight, Р597/11–Р597/17height 105 mm, 3.5 kg
Dimensions and weight, Р597/20height 90 mm, diameter 200 mm, 1.5 kg

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

For small capacitances, choose a multi-value measure: Р597/1 (1–4 pF, class 0.2) or Р597/2 (10–40 pF, class 0.05). For 100–4000 pF, use the single-value measures Р597/3 to Р597/10, class 0.05 (up to 100000 Hz, up to 100 V). For 0.01–1.0 µF, use measures Р597/11 to Р597/19, class 0.1 (up to 10000 Hz, up to 20 V).

Similar products

Test and measurement

Request a price and lead time

Р597 — standard capacitance measures, set of 19 (1 pF – 1.0 µF). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.