Reflekt / Transflekt — time-domain reflectometers (TDR) for locating LV cable faults

Reflekt and Transflekt are LV cable fault locators based on time-domain reflectometry (TDR). Reflekt is a portable automatic instrument with IP65 and a QVGA 320×240 display, while Transflekt is a fixed monitor for 440 V, 50 Hz networks that catches intermittent faults. Transflekt ranges are 250–2000 m.

Reflekt
automatic TDR; single-, two- and three-phase networks, live and dead; QVGA 320×240 display; Li-Ion 4600 mAh, 4 h charge; −20…+60 °C; IP65
Transflekt
transient fault TDR monitor 440 V RMS, 50 Hz; ranges 250/500/1000/2000 m; resolution 1–8 m (VF 0.67); pulse 5 V, 120–960 ns; gain −20…+42 dB
Transflekt — communication
4G to gateway, Wi-Fi and web server
Connection
crocodile clips, optional Rogowski belts

Technical specifications

Reflektautomatic TDR; single-, two- and three-phase networks, live and dead; QVGA 320×240 display; Li-Ion 4600 mAh, 4 h charge; −20…+60 °C; IP65
Transflekttransient fault TDR monitor 440 V RMS, 50 Hz; ranges 250/500/1000/2000 m; resolution 1–8 m (VF 0.67); pulse 5 V, 120–960 ns; gain −20…+42 dB
Transflekt — communication4G to gateway, Wi-Fi and web server
Connectioncrocodile clips, optional Rogowski belts

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Reflekt interprets complex reflectograms itself and gives a result with a confidence level, so less experienced staff can work with it. “Expert” mode opens all TDR parameters and a real-time comparison of six conductor combinations. The instrument is connected to all cores at once, without re-switching pairs, in single-, two- and three-phase networks, live and dead, and only the number of phases, the position of the link or fuse, the velocity factor and the fault type are entered. It is powered by a 4600 mAh lithium-ion battery, charged in 4 h from 12 V or the mains, temperature range −20…+60 °C. Transflekt does not stress the cable with an raised voltage that could damage it further, but waits for the defect to show up at working voltage. It continuously records voltage, current and reflectograms, and during an event sends them to a remote server. Connection is by clips without changing the circuit, with Rogowski belts if needed, ranges 250/500/1000/2000 m, resolution 1–8 m at VF 0.67, pulse 5 V with a duration of 120–960 ns, gain −20…+42 dB. Communication is by 4G to a gateway, and locally through a Wi-Fi access point and web server. Several devices allow the location to be triangulated on branched networks.

How to choose

For a field crew that needs a result on site, take Reflekt, which is compatible with Rezap Faultmaster. When the defect is intermittent and cannot be found by testing the cable, install Transflekt. It is designed for a 440 V, 50 Hz network. After that, the Snoopi gas analyzer is used to confirm the place on the ground.

Request a price and lead time

Reflekt / Transflekt — time-domain reflectometers (TDR) for locating LV cable faults. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

In which networks does Reflekt work?

In single-, two- and three-phase LV cable networks, live and dead, with IP65 and a temperature range of −20…+60 °C.

How long does the Reflekt battery take to charge?

The 4600 mAh lithium-ion battery charges in 4 h from 12 V or from the mains.

What ranges and resolution does Transflekt have?

Ranges of 250, 500, 1000 and 2000 m, resolution 1–8 m at a velocity factor VF of 0.67.

Why does Transflekt not test the cable with raised voltage?

Such a test can damage the cable further and lead to the wrong defect. Transflekt waits for the fault to show up at working voltage.

How does Transflekt send data?

Through 4G to a gateway, and locally through a Wi-Fi access point and web server.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.