EA ELR 21000 — dynamic regenerative test system up to 1920 kW

ELR 21000 is a modular dynamic test system based on regenerative loads with a power of up to 1920 kW at 0–1000 V and a current of up to 5120 A. It was created to test the power electronics of data centers with an 800 V DC bus under sudden load changes.

System power
0–1920 kW; up to 240 kW per rack, 30 kW steps
Voltage
0–1000 V (dynamic tests at 800 V DC)
Current
0–5120 A
Current slew rate
up to 12 A/µs at 240 kW

Technical specifications

System power0–1920 kW; up to 240 kW per rack, 30 kW steps
Voltage0–1000 V (dynamic tests at 800 V DC)
Current0–5120 A
Current slew rateup to 12 A/µs at 240 kW
Regenerationefficiency up to 95 %
Base moduleELR 21000-80 4U, 30 kW, 0–1000 V, 0–80 A

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The base module of the ELR 21000-80 system takes up 4U and delivers 30 kW at 0–1000 V and 0–80 A. Modules are installed in a rack in 30 kW steps, one rack holds up to 240 kW, and the full configuration reaches 1920 kW. The current slew rate reaches 12 A/µs at 240 kW, so the bench reproduces consumption jumps of server power supplies and 800 V bus converters. The energy absorbed during a test is not turned into heat by the system but returned to the grid with an efficiency of up to 95 %. For a laboratory this means less need for air conditioning and a lower electricity bill during long runs. The total current of up to 5120 A is reached by parallel operation of modules in several racks.

How to choose

The system is scaled to the required power, and each 30 kW adds one more ELR 21000-80 module. For a single-rack bench up to 240 kW is enough, and larger loads need several racks. When a battery has to be tested rather than power electronics, BPTS 20920-720 at 180 kW for packs or BMTS 20200-840-2 with two 60 kW channels for modules is more suitable. Fuel cells are discharged on the FCTS 20920-720 with an efficiency of up to 96,5 %.

Request a price and lead time

EA ELR 21000 — dynamic regenerative test system up to 1920 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power does one ELR 21000 rack have?

Up to 240 kW; the rack is built from 30 kW ELR 21000-80 modules. Several racks together give up to 1920 kW.

What is the current slew rate of ELR 21000?

Up to 12 A/µs at a power of 240 kW. This is enough to simulate dynamic loads on an 800 V DC bus.

Does ELR 21000 return energy to the grid?

Yes, the loads are regenerative and return the absorbed energy to the grid with an efficiency of up to 95 %.

What current and voltage are available in the ELR 21000 system?

Voltage is 0–1000 V and total current is 0–5120 A. A single ELR 21000-80 module works with a current of 0–80 A.

Can I start with one rack and expand the system later?

The design is modular: power changes in 30 kW steps up to 240 kW per rack, and then by adding racks up to 1920 kW.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.