REMIZ 3 (3B / 3PP / 3P) and REMIZ 1 — electricity meters for DIN rail TH35
Country: Poland · Model: REMIZ 3 / REMIZ 1
REMIZ is a line of compact electricity meters for DIN rail TH35 for distribution boards with limited space. The REMIZ 3 is a three-phase multi-tariff meter in versions 3B, 3PP and 3P, and the REMIZ 1 is a single-phase single-tariff meter one module (18 mm) wide. They are used for sub-metering at enterprises, in commercial and residential facilities, at charging stations and at renewable energy facilities.
- REMIZ 3B
- direct connection, 3×230/415 V, Iref 5 A, Imax 80 A
- REMIZ 3PP / 3P
- semi-indirect / indirect, 1 or 5 A, Imax 10 A; 3P: 3×57/100 V
- REMIZ 3 class
- active A or B, reactive B/C or 1/2
- REMIZ 3 communication
- optical port (DLMS, IEC 62056-21), 2×RS-485 (Modbus, DLMS), Wi-Fi option, 2 pulse outputs
Technical specifications
| REMIZ 3B | direct connection, 3×230/415 V, Iref 5 A, Imax 80 A |
|---|---|
| REMIZ 3PP / 3P | semi-indirect / indirect, 1 or 5 A, Imax 10 A; 3P: 3×57/100 V |
| REMIZ 3 class | active A or B, reactive B/C or 1/2 |
| REMIZ 3 communication | optical port (DLMS, IEC 62056-21), 2×RS-485 (Modbus, DLMS), Wi-Fi option, 2 pulse outputs |
| REMIZ 3 enclosure | 6 DIN modules (107 mm), IP51, M1/M2, E2 |
| REMIZ 1 | 1 phase, 230 V, 5(32) A, class B, M-Bus (PREMIUM), S0, 1 DIN module (18 mm), IP20 |
| Temperature | −25…+55 °C or −40…+70 °C (REMIZ 3) |
| Standards | PN-EN 50470-1, -3; PN-EN 62052-11, -31; MID |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The REMIZ 3 measures active, reactive and apparent energy in both directions in three-phase four-wire networks, where the 3B is connected directly, the 3PP semi-indirectly and the 3P indirectly. The width is 6 DIN modules (107 mm) on a TH35-7.5 rail per DIN 60715. The accuracy class is A or B for active energy and B/C or 1/2 for reactive, the voltage is 3 × 230/415 V, and for the 3P 3 × 57/100 V. The 3B has Iref 5 A and Imax 80 A, and the 3PP and 3P work with Iref 1 or 5 A and Imax 10 A. It measures power, currents, voltages, frequency, harmonics and quality indicators W1–W4, and has an event log, profiles and a clock with a supercapacitor for 120 h. Communication runs through an optical port (DLMS or PN-EN 62056-21), two RS-485 ports, two pulse outputs, and optionally a relay, a tariff input and 2.4 GHz Wi-Fi. Consumption in the voltage circuits is below 0.6 W per phase, the constant is 2 500–20 000 imp/kWh, frequency 50 Hz, temperature −25…+55 °C or −40…+70 °C, IP51, classes M1 or M2 and E2. The REMIZ 1 has 230 V, Iref 5 A, Imax 32 A, class B, an S0 pulse output per DIN 43864, and in the PREMIUM version also M-Bus.
How to choose
The network type determines the model. For a three-phase network with direct connection the REMIZ 3B is used, and with current transformers the REMIZ 3PP or 3P. The REMIZ 1 is intended for a single-phase two-wire network, IP20. Compliance with PN-EN 50470-1, PN-EN 50470-3, PN-EN 62052-11 and PN-EN 62052-31.
Request a price and lead time
REMIZ 3 (3B / 3PP / 3P) and REMIZ 1 — electricity meters for DIN rail TH35. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How does REMIZ 3B differ from 3PP and 3P?
The 3B is connected directly, the 3PP semi-indirectly, the 3P indirectly via transformers.
How much space does REMIZ take on a DIN rail?
The REMIZ 3 takes 6 DIN modules (107 mm), the REMIZ 1 one module (18 mm).
What ports does REMIZ 3 have?
An optical port, two RS-485 and two pulse outputs, optionally 2.4 GHz Wi-Fi.
What is the operating temperature of REMIZ 3?
From −25 to +55 °C or from −40 to +70 °C depending on the version.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.