С503–С511 — laboratory AC/DC voltmeters
Country: Ukraine · Model: С503, С504, С505, С506, С507, С508, С509, С510, С511
accuracy class 0.5 · 30 V – 3 kV · 45 Hz – 3·10⁶ Hz (working range) · AC and DC
The С503–С511 series comprises analogue laboratory voltmeters of accuracy class 0.5. They measure DC voltage and AC voltage over a wide frequency band. The nine versions differ in the upper limit of the measuring range, from 30 V (С503) to 3 kV (С511). The normal frequency range starts at 45 Hz. For the С503–С509 it extends to 1·10⁶ Hz, with a working range up to 2.5·10⁶ Hz. For the С510 and С511 the normal range reaches 1.5·10⁶ Hz and the working range 3·10⁶ Hz. The voltmeter is a restorable, repairable instrument. Overall dimensions are (205 ± 1.45) × (290 ± 1.6) × (135 ± 2.0) mm, and the weight does not exceed 3.6 kg. A П5114 transformer for powering the scale illuminator is supplied. Typical uses are direct voltage measurements in laboratories and verification of less accurate instruments.
- Accuracy class
- 0.5
- Measured voltage
- DC and AC
- Measuring range upper limits
- С503 – 30 V; С504 – 75 V; С505 – 150 V; С506 – 300 V; С507 – 450 V; С508 – 600 V; С509 – 1 kV; С510 – 1.5 kV; С511 – 3 kV
- Normal frequency range (С503–С509)
- 45 to 1·10⁶ Hz
Technical specifications
| Accuracy class | 0.5 |
|---|---|
| Measured voltage | DC and AC |
| Measuring range upper limits | С503 – 30 V; С504 – 75 V; С505 – 150 V; С506 – 300 V; С507 – 450 V; С508 – 600 V; С509 – 1 kV; С510 – 1.5 kV; С511 – 3 kV |
| Normal frequency range (С503–С509) | 45 to 1·10⁶ Hz |
| Working frequency range (С503–С509) | above 1·10⁶ to 2.5·10⁶ Hz |
| Normal frequency range (С510, С511) | 45 to 1.5·10⁶ Hz |
| Working frequency range (С510, С511) | above 1.5·10⁶ to 3·10⁶ Hz |
| Product type | restorable, repairable |
| Overall dimensions | (205 ± 1.45) × (290 ± 1.6) × (135 ± 2.0) mm |
| Weight | max. 3.6 kg |
| Scope of supply | voltmeter – 1 pc; П5114 transformer (illuminator supply) – 1 pc; shade – 1 pc; ОП4-4-2 lamp – 3 pcs; technical description and operating manual – 1 copy; passport – 1 copy |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Select the model by the upper limit of the measuring range: С503 – 30 V, С504 – 75 V, С505 – 150 V, С506 – 300 V, С507 – 450 V, С508 – 600 V, С509 – 1 kV, С510 – 1.5 kV, С511 – 3 kV. For frequencies above 2.5·10⁶ Hz, only the С510 and С511 are suitable, as their working range extends to 3·10⁶ Hz.
Similar products
Request a price and lead time
С503–С511 — laboratory AC/DC voltmeters. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.