TCIDL-MID / TCIDL1-MID / TCIDL2-MID / TCIDL3-MID three-phase direct-connection meters with MID certificate
Country: Spain · Model: TCIDL-MID / TCIDL1-MID / TCIDL2-MID / TCIDL3-MID
TCIDL-MID, TCIDL1-MID, TCIDL2-MID and TCIDL3-MID are three-phase direct-connection meters for 3×230/400 V networks with a current of 0.25–5(80) A or 0.25–5(100) A. The MID 2014/32/EU certificate makes them suitable for billing metering, including re-invoicing tenants and sub-subscribers.
- Rated voltage
- 3×230/400 V AC
- Current
- 0.25–5(80) A (TCIDL-MID, TCIDL1-MID, TCIDL2-MID); 0.25–5(100) A (TCIDL3-MID)
- Accuracy class
- active energy — class B (EN 50470-3); reactive — class 2 (EN 62053-23, TCIDL3-MID)
- Certification
- MID 2014/32/EU
Technical specifications
| Rated voltage | 3×230/400 V AC |
|---|---|
| Current | 0.25–5(80) A (TCIDL-MID, TCIDL1-MID, TCIDL2-MID); 0.25–5(100) A (TCIDL3-MID) |
| Accuracy class | active energy — class B (EN 50470-3); reactive — class 2 (EN 62053-23, TCIDL3-MID) |
| Certification | MID 2014/32/EU |
| Metering | bidirectional (import/export), 4 quadrants, up to 4 tariffs (TCIDL-MID, TCIDL3-MID) |
| Communication | RS485 Modbus RTU, IR port (EN 62056); pulse output SO (DIN 43864) |
| Mounting | DIN rail, 4 modules (TCIDL1-MID) |
| Insulation | 4 kV, 1 min |
| Standards | EN 50470-1/-3, EN IEC 62053-21/-22/-23, IEC 62052-11, IEC 62052-31, EN 61010 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
TCIDL1-MID meters active energy in a three-phase three- or four-wire network, class B, and has an SO pulse output to DIN 43864 up to 24 V DC and 20 mA, 4 kV insulation for 1 min and a 4-module DIN housing. TCIDL2-MID is self-powered, measures active energy (including exported energy, resettable over RS485), frequency, phase voltages, currents and powers, complies with class B under EN 50470-3:2022 and EN IEC 62053-21:2021, and works over Modbus. TCIDL-MID combines a meter and a network analyzer, meters active and reactive energy in both directions on 4 tariffs, has RS485 (Modbus RTU, up to 9600 baud) and an IR port per EN 62056, and links up to 32 instruments in a line or 128 through a converter. TCIDL3-MID works at 0.25–5(100) A, has bidirectional metering of active (class B, EN 50470-1) and reactive energy (class 2, EN 62053-23) in four quadrants, 4 tariffs and a display with 6 integer and 2 decimal digits; a TCIDL3i-MID version is also available.
How to choose
For commercial metering with one energy direction, TCIDL1-MID is enough. If frequency, phase voltages and export are needed, take TCIDL2-MID, and for bidirectional metering of reactive energy and tariffs, TCIDL-MID or TCIDL3-MID for 0.25–5(100) A. For currents above 80 A only TCIDL3-MID will do. For technical metering without MID, TCIL2 or TCIDL1 is enough.
Request a price and lead time
TCIDL-MID / TCIDL1-MID / TCIDL2-MID / TCIDL3-MID three-phase direct-connection meters with MID certificate. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What does the MID certificate give?
Compliance with directive MID 2014/32/EU gives the right to use the meters for billing metering, including for tenants and sub-subscribers.
How many meters can be linked over RS485?
Up to 32 instruments in one line or up to 128 through a converter, at up to 9600 baud, using the Modbus RTU protocol.
What are the general electrical characteristics of the meters?
Rated voltage 3×230/400 V AC, operating range ±30 % Un, own consumption in the current circuit below 0.5 VA.
Which standards do these meters comply with?
EN 50470-1, EN 50470-3, EN 62053-21/-22/-23, IEC 62052-11, IEC 62052-31 and EN 61010. They work with the SACIGEST and TTIGEST software and data concentrators.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.