ВАФ-85-М1 — AC volt-ampere-phase meter

0.2–500 V · 0.2–250 mA · 180–0–180° · accuracy class 4.0 / 1.5 (phase)

The ВАФ-85-М1 is an analogue volt-ampere-phase meter for measuring the RMS values of sinusoidal AC current and voltage, as well as the phase shift angle relative to a three-phase voltage system with nominal values of 110, 220 and 380 V. Current can be measured either by breaking the circuit (2–250 mA in three ranges) or without breaking it (0.2–10 mA). Voltage is measured in six ranges from 0.2 to 500 V, and the phase angle is read on a 180–0–180° scale. The accuracy class is 4.0 for current and voltage and 1.5 for phase. The limit of reading variation is 0.75 %, and the insulation withstands a 2 kV test voltage for 1 min. The instrument weighs no more than 3.5 kg and measures 260 × 160 × 185 mm. It is intended for commissioning and testing relay protection schemes and power circuits, and for the adjustment, repair and operation of electrical installations in enclosed, climate-controlled rooms.

AC current (with circuit break)
2–10, 10–50, 50–250 mA
AC current (without circuit break)
0.2–1, 1–5, 2–10 mA
AC voltage
0.2–1, 1–5, 5–25, 25–125, 50–250, 100–500 V
Phase shift angle
180–0–180°

Technical specifications

AC current (with circuit break)2–10, 10–50, 50–250 mA
AC current (without circuit break)0.2–1, 1–5, 2–10 mA
AC voltage0.2–1, 1–5, 5–25, 25–125, 50–250, 100–500 V
Phase shift angle180–0–180°
Accuracy class (current, voltage)4.0
Intrinsic error limits (current, voltage)±4.0 %
Accuracy class (phase)1.5
Intrinsic error limits (phase)±1.5 %
Nominal voltages of three-phase system110; 220; 380 V
Limit of reading variation0.75 %
Insulation test voltage2 kV, (50±1) Hz, 1 min
Short-time overloads10 surges of no more than 0.5 s at 15 s intervals
Dimensions260 × 160 × 185 mm
Weight, max3.5 kg

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

For currents from 2 to 250 mA, use the circuit-break mode (ranges 2–10, 10–50 and 50–250 mA). For small currents of 0.2–10 mA, where the circuit must not be disturbed, use the no-break mode. Select the voltage range immediately above the expected value, from 0.2–1 V up to 100–500 V.

Similar products

Test and measurement

Request a price and lead time

ВАФ-85-М1 — AC volt-ampere-phase meter. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.