BVD / PTL / DM / CTL / CIT / IER testers and measuring instruments up to 1000 V
Country: Spain · Model: BVD / PTL / DM / CTL / CIT / IER
The testers and measuring instruments BVD, PTL, DM, CTL, CIT, CRT, IER and IPR check for the absence of voltage and measure the parameters of electrical installations up to 1000 V. The range complies with IEC 61010-1, and the voltage detectors with IEC 61243-3. The instruments are used during commissioning and operation in buildings, at industrial sites and in substations.
- BVD-1000 / BVD-1500
- two-pole testers: AC/DC voltage, phase sequence (57–400 V), RCD test 30–40 mA, continuity; IP65; CAT IV 600 V / CAT III 1000 V; IEC 61243-3
- PTL-1000
- non-contact indicator 12–1000 V AC, CAT III 1000 V / CAT IV 600 V
- BTL-600
- compact True RMS multimeter with NCV
- DM-600
- multimeter 600 V AC/DC, 10 A, 20 MΩ, 2 mF, 20 kHz, NCV
Technical specifications
| BVD-1000 / BVD-1500 | two-pole testers: AC/DC voltage, phase sequence (57–400 V), RCD test 30–40 mA, continuity; IP65; CAT IV 600 V / CAT III 1000 V; IEC 61243-3 |
|---|---|
| PTL-1000 | non-contact indicator 12–1000 V AC, CAT III 1000 V / CAT IV 600 V |
| BTL-600 | compact True RMS multimeter with NCV |
| DM-600 | multimeter 600 V AC/DC, 10 A, 20 MΩ, 2 mF, 20 kHz, NCV |
| CTL-1000 | True RMS clamp meter: 1000 V AC/DC, 1000 A AC, 6000 counts, NCV |
| CIT-10 | megohmmeter 0.01 MΩ–10 GΩ, test voltages from 50 V |
| CRT-1200 | clamp for measuring earth resistance without breaking the circuit, CAT III 600 V |
| IER-4000 | earth resistance meter using the 2- and 3-pole method, memory of 100 measurements |
| IPR-400 | phase sequence and motor rotation direction indicator, 120–400 V AC |
| Safety standard | IEC 61010-1 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The two-pole testers BVD-1000 and BVD-1500 measure AC/DC voltage, show the phase sequence at 57–400 V 50–60 Hz, test RCDs with a current of 30–40 mA at 230 V and check continuity. The BVD-1000 housing has IP65 and CAT IV 600 V / CAT III 1000 V, is powered by two AAA batteries, and switches off automatically after about 30 s. The non-contact PTL-1000 works at 12–1000 V and 48–1000 V AC and distinguishes phase from neutral. The multimeter DM-600 measures up to 600 V, 10 A, 20 MΩ, 2 mF and 20 kHz, and BTL-600 is a compact True RMS unit with NCV. The True RMS clamp meter CTL-1000 with 6000 counts measures up to 1000 V and 1000 A AC. The megohmmeter CIT-10 covers 0.01 MΩ–10 GΩ for cables, motors and transformers. Earthing is checked with the clamp CRT-1200 without disconnecting the earth electrode, and with IER-4000 using the 2- or 3-pole method with a memory of 100 groups of measurements. The indicator IPR-400 determines the phase sequence and motor rotation direction without probes.
How to choose
The choice depends on the task. For absence of voltage and RCD testing take BVD-1000 or BVD-1500 with a wider voltage range, and for a quick check without contact PTL-1000. Current up to 1000 A without breaking the circuit is measured by CTL-1000, and resistance up to 20 MΩ and capacitance by DM-600. The insulation of cables and motors is checked by CIT-10, earthing by CRT-1200 or IER-4000, and IPR-400 works in the 120–400 V AC range.
Request a price and lead time
BVD / PTL / DM / CTL / CIT / IER testers and measuring instruments up to 1000 V. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What phase sequence and voltage does BVD-1000 show?
Phase sequence in the range 57–400 V 50–60 Hz, and it tests RCDs with a current of 30–40 mA at 230 V.
What overvoltage category and protection does BVD-1000 have?
IP65 and CAT IV 600 V / CAT III 1000 V. The instrument is powered by two AAA batteries.
What is used to measure earth resistance without disconnecting the earth electrode?
The CRT-1200 clamp; IER-4000 works with the 2- and 3-pole method with a memory of 100 groups.
What resistance range does the CIT-10 megohmmeter have?
0.01 MΩ–10 GΩ, test voltages from 50 V. Suitable for cables, motors and transformers.
What do the CTL-1000 clamp meters measure?
AC current up to 1000 A and AC/DC voltage up to 1000 V in True RMS mode, with a 6000-count display.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.