EPack Lite and EFit — entry-level thyristor power controllers, 1/2/3 phase, up to 125 A, up to 500 V

EFit is a single-phase thyristor controller up to 50 A and 500 V on a DIN rail, and EPack Lite is its bigger relative for currents up to 125 A in single-, two- and three-phase versions. Both series are intended for typical heating where advanced diagnostics and fieldbuses are not needed.

EPack Lite
1PH, 2PH, 3PH; up to 125 A; up to 500 V; phase-angle and burst control; constant-resistance loads and transformer primary windings
EFit
single-phase, up to 50 A, up to 500 V; phase-angle and burst control; current limiting; analog and logic input; no digital communication; DIN-rail mounting, plug-in terminals; linearity better than ±2 % with mains fluctuations
EFit loads
constant and variable resistance, short-wave IR emitters, transformer loads
Replacement
EFit replaces the TE10A in form and mounting

Technical specifications

EPack Lite1PH, 2PH, 3PH; up to 125 A; up to 500 V; phase-angle and burst control; constant-resistance loads and transformer primary windings
EFitsingle-phase, up to 50 A, up to 500 V; phase-angle and burst control; current limiting; analog and logic input; no digital communication; DIN-rail mounting, plug-in terminals; linearity better than ±2 % with mains fluctuations
EFit loadsconstant and variable resistance, short-wave IR emitters, transformer loads
ReplacementEFit replaces the TE10A in form and mounting

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Install it, connect it, and the controller works; this simplicity is valued in both series. EPack Lite is designed for constant-resistance heaters and transformer primary windings, and current and voltage measurements make it possible to generate alarms. EFit works in phase-angle and burst modes, limits current and accepts an analog and logic signal. It suits constant and variable resistance heaters, IR emitters and transformer loads. Both series meet international requirements for quality, noise immunity and emissions.

How to choose

The selection criteria are the number of phases and current. One phase up to 50 A means the EFit, a three-phase or two-phase load up to 125 A means the EPack Lite. The two-phase version is more economical for balanced loads, and the three-phase one is needed when the phases are loaded unevenly. If digital communication is also needed up to 125 A and 500 V, choose the EPack, and above 125 A the modular EPower.

Request a price and lead time

EPack Lite and EFit — entry-level thyristor power controllers, 1/2/3 phase, up to 125 A, up to 500 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which controller should be used for a single-phase 50 A heater?

The EFit is designed precisely for single-phase installations up to 50 A and 500 V, needs no setup and is mounted on a DIN rail.

Which phase versions does EPack Lite have?

Single-phase, two-phase for a three-phase load, and three-phase, for currents up to 125 A.

Does EFit hold power during mains dips?

Yes, it compensates voltage fluctuations by itself. If the voltage changed by 10 %, the power without compensation would change by 20 %, while EFit holds linearity better than ±2 %.

Which heaters does EFit work with?

Constant and variable resistance heaters, short-wave IR emitters and transformer loads.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.