EPack — compact thyristor power controller, 1/2/3 phase, up to 125 A, up to 500 V

EPack measures load currents and voltage and regulates power by its true value, so it is installed on furnaces and heating installations. The range is up to 125 A at 100–500 V, in 1PH, 2PH and 3PH versions.

Versions
1PH single-phase; 2PH three-phase load, two phases controlled; 3PH all three phases controlled
Rated current
1PH: 1–125 A; range up to 125 A
Voltage
100–500 V
Modes
phase-angle control, burst firing

Technical specifications

Versions1PH single-phase; 2PH three-phase load, two phases controlled; 3PH all three phases controlled
Rated current1PH: 1–125 A; range up to 125 A
Voltage100–500 V
Modesphase-angle control, burst firing
Regulationby true power; current limiting
Loadsconstant and variable resistance, short-wave IR emitters, loads through a transformer
Diagnosticsload break and partial load break (PLF/PLU), alarms; in 3PH, per-phase measurements, impedance, energy counter, reactive power
Inputsanalog and logic
CommunicationEtherNet/IP, Modbus TCP, ProfiNet; EtherCAT for 1PH
Cybersecurityenhanced protection (according to the manufacturer)

Replacement for

ROT-63 (EPack-1PH, single-phase, up to 125 A, up to 500 V)

selected by purpose and main parameters, please confirm with the manager

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The controller works with constant and variable resistance heaters, short-wave IR emitters and transformer loads. Phase-angle control and burst firing are available, as well as current limiting. Analog and logic inputs accept signals from the control system. The manufacturer specifically notes enhanced protection against cyber threats. The 1PH, 2PH and 3PH versions of the same series share the same setup logic, so a single configuration program and one type of spare parts are enough for a plant. The controllers are designed to be mounted in the cabinet with no gaps between units, and commissioning takes minutes.

How to choose

Up to 125 A the EPack itself is enough, and beyond that limit move to the modular EPower. When choosing between 2PH and 3PH, look at the phase balance of the load. The single-phase 1PH for 1–125 A replaces the ROT-63 and other low-current controllers if digital communication with a PLC is needed. For simple heating without diagnostics and fieldbuses there are the EPack Lite up to 125 A and the EFit up to 50 A.

Request a price and lead time

EPack — compact thyristor power controller, 1/2/3 phase, up to 125 A, up to 500 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What mains voltage does EPack support?

The operating voltage is 100–500 V.

Does EPack have protection against cyber threats?

The manufacturer declares enhanced protection against cyber threats.

Can EPack replace the ROT-63?

The single-phase EPack-1PH for 1–125 A is suitable for replacing the ROT-63 and other low-current controllers. Selection is by load current and heater type.

Which loads does EPack support?

Constant and variable resistance heaters, short-wave IR emitters and transformer loads.

Which control mode does EPack use?

Phase-angle control or burst firing with whole cycles, with regulation by true power and current limiting. Burst mode creates no harmonics.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.