Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

THYRISTOR POWER CONTROLLERS

EPower — modular thyristor power controller 50–630 A (up to 4000 A in remote version), up to 690 V

EPower consists of one control module and up to four power modules. Compact units cover 50–630 A, remote MC units 800–4000 A, and mains voltage reaches 690 V. Typical applications are vacuum and atmospheric furnaces, glass, plastics moulding and autoclaves.

Rated current
compact version 50–630 A; remote (MC) 800–4000 A
Rated voltage
up to 690 V
Configurations
up to 4 power modules per control module: 1–4 independent single-phase loops, 1–2 two-phase, three-phase
Modes
phase-angle control, burst firing

Technical specifications

Rated currentcompact version 50–630 A; remote (MC) 800–4000 A
Rated voltageup to 690 V
Configurationsup to 4 power modules per control module: 1–4 independent single-phase loops, 1–2 two-phase, three-phase
Modesphase-angle control, burst firing
Regulationby true power, voltage, current; current limiting
Loadsconstant and variable resistance, short-wave IR emitters, loads through a transformer
Diagnosticsload break and partial load break (PLF/PLU), alarms
Inputsanalog and logic
CommunicationModbus RTU (RS485), Modbus TCP, Profibus, ProfiNet, EtherNet/IP, DeviceNet, CC-Link
Network load managementPredictive Load Management (PLM), power sharing between installations
SetupQuickStart, graphical link editor

Replacement for

ROT-63, ROT-160, ROT-250E (including 700 V version), ROT-630, ROT-630M, ROT-800E, ROT-1400E, ROT-2600E (single-phase control; compact modules 50–630 A, separate-mount version 800–4000 A, up to 690 V)

selected by purpose and main parameters, please confirm with the manager

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Communication with the PLC runs over the selected fieldbus, and the power modules are mounted in the cabinet next to the load. Available are RS485 Modbus RTU, Modbus TCP, Profibus, ProfiNet, EtherNet/IP, DeviceNet and CC-Link. The Predictive Load Management function distributes power between installations and smooths consumption peaks. The QuickStart wizard speeds up commissioning, and complex schemes are built in the graphical link editor. Analog and logic inputs accept setpoint signals. ROT series controllers from ROT-63 to ROT-2600E, including the 700 V version, can be replaced with EPower loops selected by load current, mains voltage and heater type.

How to choose

First determine the current of each loop. If it does not exceed 630 A, the compact power module is used, and from 800 A the remote version. The number of loops equals the number of power modules per control module, up to four. For currents up to 125 A and voltage up to 500 V the range has the more compact EPack.

Request a price and lead time

EPower — modular thyristor power controller 50–630 A (up to 4000 A in remote version), up to 690 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What control modes does EPower have?

Phase-angle control and burst firing with whole cycles. Regulation is by true power, voltage or current with current limiting.

How can EPower be set up quickly?

The QuickStart wizard speeds up commissioning, and the firing mode, load type and number of phases are set in software through the control module.

What load diagnostics does EPower have?

Full and partial load break (PLF/PLU) and alarms.

Which heaters does EPower work with?

Constant and variable resistance heaters, short-wave IR emitters, and also loads through a transformer.

Is there an EPower for 4000 A?

Yes, the remote MC version is made for 800–4000 A, the compact one for 50–630 A.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.