UC DC UPS / thyristor rectifier 0.5–50 kVA
Country: Italy · Model: UC
UC thyristor rectifier-chargers of 0.5–50 kVA supply DC networks with voltages from 24 to 400 V. The main field of use is substation operational DC systems and industrial automation, where relay protection, breaker drives and controllers run from a storage battery.
- Power
- 0.5–50 kVA (UC-1…UC-16)
- Input
- 1-ph. or 3-ph. + N
- DC output voltage
- 24 / 36 / 48 / 72 / 110 / 150 / 220 / 400 V
- Technology
- thyristor
Technical specifications
| Power | 0.5–50 kVA (UC-1…UC-16) |
|---|---|
| Input | 1-ph. or 3-ph. + N |
| DC output voltage | 24 / 36 / 48 / 72 / 110 / 150 / 220 / 400 V |
| Technology | thyristor |
| Batteries | sealed lead-acid (NiCd / Li-Ion / NaNiCl2 on request) |
| Protection degree | IP20 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The unit works as a DC UPS: the rectifier supplies the load and at the same time keeps the storage battery on float charge, and when the mains disappears the load transfers to the battery without interruption. The thyristor circuit tolerates heavy duty well and has long been established in the power industry. The input is single-phase or three-phase with neutral, and the range is designated UC-1…UC-16. The standard output voltages of 24, 36, 48, 72, 110, 150, 220 and 400 V cover 24 V automation, 48 V communications, and 110 or 220 V substation operational current. Sealed lead-acid batteries are fitted, with NiCd, Li-Ion or NaNiCl2 on request. The IP20 enclosure is intended for electrical rooms and relay halls.
How to choose
The output voltage is set by the load: for substation relay protection it is usually 110 or 220 V, for automation 24 V, for communications 48 V. Power is calculated as the sum of the constant load and the battery charging current, so the rectifier is taken with a margin. If consumers need AC, look at the Futura online UPS of 5–800 kVA or Mizar of 2–10 kVA.
Request a price and lead time
UC DC UPS / thyristor rectifier 0.5–50 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What output voltages does the UC rectifier have?
The standard range is 24, 36, 48, 72, 110, 150, 220 or 400 V DC.
Is UC suitable for substation operational current?
Yes, the series is designed for substation operational DC systems and industrial automation, and the 110 and 220 V voltages are in the standard range.
What is the power of UC rectifiers?
The UC-1…UC-16 range covers 0.5–50 kVA with a single-phase or three-phase input with neutral.
Which batteries work with the UC DC UPS?
Sealed lead-acid as standard, NiCd, Li-Ion or NaNiCl2 on request.