SEC-HCP — rack-mount DC power system N+1, 12/24/48 V, 100 A
Country: Netherlands · Model: SEC-HCP
The SEC-HCP rack-mount DC system builds 100 A from 4 rectifier modules and delivers 14.2, 28.4 or 56.8 V DC, the float voltage for 12, 24 and 48 V batteries. The 19-inch chassis takes 1U. It goes into telecom nodes, server rooms and IT cabinets.
- Output
- 14.2 V / 28.4 V / 56.8 V DC
- Current
- 100 A (4 modules), up to 200 A in parallel connection
- Redundancy
- N+1 with load sharing
- Input
- 100–240 V AC
Technical specifications
| Output | 14.2 V / 28.4 V / 56.8 V DC |
|---|---|
| Current | 100 A (4 modules), up to 200 A in parallel connection |
| Redundancy | N+1 with load sharing |
| Input | 100–240 V AC |
| Form factor | 19", 1U |
| Monitoring | SNMP, web interface, e-mail, Form C dry contacts |
| Battery charging | built-in 2-stage charger |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504408200 |
| CN code (EU) | 85044083 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
The modules run with N+1 redundancy and load sharing, splitting the current between them. N+1 means that if one module fails, the others keep the load powered without a break. With systems connected in parallel, current reaches 200 A. Mains input is 100–240 V AC. A battery bank connects to the bus, and together they work as a DC UPS, with the battery carrying the load during an outage and the built-in 2-stage charger topping it up once mains returns. Status is visible over SNMP, a web interface and e-mail, and the changeover Form C dry contacts feed external alarms or a supervisory system.
How to choose
Pick the output by the battery, 14.2 V for a 12 V bus, 28.4 V for 24 V and 56.8 V for 48 V. Size current as the load plus the battery recharge current after an outage. With N+1, plan the working current without one module, or a module failure leaves no margin. If 100 A is not enough, systems run in parallel up to 200 A. For 230 V loads in the same rack, the SRI inverter at 1,200 W in 1U or 2,200 W in 2U connects to the same 24 or 48 V battery, and a single device up to 35 A without redundancy needs only a SEC supply.
Request a price and lead time
SEC-HCP — rack-mount DC power system N+1, 12/24/48 V, 100 A. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the maximum current of the SEC-HCP?
One system with 4 modules gives 100 A, and up to 200 A in parallel connection.
Which output voltages does the SEC-HCP offer?
14.2, 28.4 and 56.8 V DC for 12, 24 and 48 V battery systems.
How is the SEC-HCP monitored remotely?
Over SNMP, a web interface, e-mail and Form C dry contacts.
What happens if one rectifier module fails?
The remaining modules keep the load powered, which is what N+1 means. The alarm goes out over SNMP or the Form C contacts.
Can the SEC-HCP charge a battery bank?
Yes, a 2-stage charger is built in. The battery connects to the 14.2, 28.4 or 56.8 V output bus.