SEC-HCP — rack-mount DC power system N+1, 12/24/48 V, 100 A

The SEC-HCP rack-mount DC system builds 100 A from 4 rectifier modules and delivers 14.2, 28.4 or 56.8 V DC, the float voltage for 12, 24 and 48 V batteries. The 19-inch chassis takes 1U. It goes into telecom nodes, server rooms and IT cabinets.

Output
14.2 V / 28.4 V / 56.8 V DC
Current
100 A (4 modules), up to 200 A in parallel connection
Redundancy
N+1 with load sharing
Input
100–240 V AC

Technical specifications

Output14.2 V / 28.4 V / 56.8 V DC
Current100 A (4 modules), up to 200 A in parallel connection
RedundancyN+1 with load sharing
Input100–240 V AC
Form factor19", 1U
MonitoringSNMP, web interface, e-mail, Form C dry contacts
Battery chargingbuilt-in 2-stage charger
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408200
CN code (EU)85044083

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The modules run with N+1 redundancy and load sharing, splitting the current between them. N+1 means that if one module fails, the others keep the load powered without a break. With systems connected in parallel, current reaches 200 A. Mains input is 100–240 V AC. A battery bank connects to the bus, and together they work as a DC UPS, with the battery carrying the load during an outage and the built-in 2-stage charger topping it up once mains returns. Status is visible over SNMP, a web interface and e-mail, and the changeover Form C dry contacts feed external alarms or a supervisory system.

How to choose

Pick the output by the battery, 14.2 V for a 12 V bus, 28.4 V for 24 V and 56.8 V for 48 V. Size current as the load plus the battery recharge current after an outage. With N+1, plan the working current without one module, or a module failure leaves no margin. If 100 A is not enough, systems run in parallel up to 200 A. For 230 V loads in the same rack, the SRI inverter at 1,200 W in 1U or 2,200 W in 2U connects to the same 24 or 48 V battery, and a single device up to 35 A without redundancy needs only a SEC supply.

Request a price and lead time

SEC-HCP — rack-mount DC power system N+1, 12/24/48 V, 100 A. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the maximum current of the SEC-HCP?

One system with 4 modules gives 100 A, and up to 200 A in parallel connection.

Which output voltages does the SEC-HCP offer?

14.2, 28.4 and 56.8 V DC for 12, 24 and 48 V battery systems.

How is the SEC-HCP monitored remotely?

Over SNMP, a web interface, e-mail and Form C dry contacts.

What happens if one rectifier module fails?

The remaining modules keep the load powered, which is what N+1 means. The alarm goes out over SNMP or the Form C contacts.

Can the SEC-HCP charge a battery bank?

Yes, a 2-stage charger is built in. The battery connects to the 14.2, 28.4 or 56.8 V output bus.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.