TriMOD — modular three-phase UPS, 10–80 kW

A modular three-phase online UPS rated 10–80 kW, with a parallel system reaching 160 kW. It is assembled from single-phase power modules and holds an output power factor of 1 at up to 96.5 % efficiency. Typical sites are server rooms and data centers where IT loads need N+X redundancy.

Power
10–80 kW; up to 160 kW in parallel
Output power factor (cos φ)
1
Topology
online, VFI-SS-11
Efficiency
up to 96.5 %

Technical specifications

Power10–80 kW; up to 160 kW in parallel
Output power factor (cos φ)1
Topologyonline, VFI-SS-11
Efficiencyup to 96.5 %
Phase configuration3/3 or 3/1, single-phase power modules
RedundancyN+X, hot-swappable modules and battery drawers
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

TriMOD is classed as online VFI-SS-11, so output voltage and frequency do not depend on the state of the mains. Because the power modules are single-phase, a three-phase supply can feed either a three-phase output (3/3) or a single-phase one (3/1). The second option helps when the whole protected load is single-phase and splitting it across three phases is awkward. Redundancy sits at two levels, in the modules and in the cabinets. Power modules and battery drawers are hot-swapped while the load stays powered. An output power factor of 1 means the kW rating equals the kVA rating, so the sizing needs no margin for the power factor of IT equipment.

How to choose

Work out the load in kW and add at least one module beyond what is needed, which gives an N+1 layout. Choose 3/3 for three-phase consumers and evenly spread racks, and 3/1 for a single-phase load fed from a three-phase supply. If the total goes past 160 kW, move to Keor MOD+ with 420 and 600 kW cabinets. For emergency lighting and smoke extraction under EN 50171, TRIMOD MCS covers a similar 3–80 kW range.

Request a price and lead time

TriMOD — modular three-phase UPS, 10–80 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How much power can TriMOD reach in parallel?

A single unit delivers 10–80 kW, and a parallel system up to 160 kW. Inside a cabinet, power grows as power modules are added.

Can TriMOD give a single-phase output from a three-phase input?

Yes. Besides 3/3, the 3/1 configuration is supported, built on the same single-phase power modules.

What is the efficiency of TriMOD?

The maker states up to 96.5 % efficiency with the online VFI-SS-11 topology, that is, in double conversion.

Can TriMOD modules be replaced without shutting down the load?

Yes, power modules and battery drawers are hot-swappable. While a failed module is out, the spare modules of the N+X layout carry the load.

How does TriMOD differ from TRIMOD MCS?

TriMOD, rated 10–80 kW, targets IT loads and data centers. TRIMOD MCS, rated 3–80 kW, is built to EN 50171 as a central power system for emergency lighting and safety equipment.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.