Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

UPS AND POWER SUPPLIES

DPS — industrial IGBT UPS

The industrial DPS UPS on IGBT transistors belongs to class VFI-SS-111 under IEC/EN 62040 and is designed for harsh operating conditions. Its main distinction is high tolerance to short-circuit currents, so a faulty line can be selectively disconnected by a breaker without stopping the whole UPS.

Classification
VFI-SS-111 per IEC/EN 62040
Control
dual DSP + PLD for the rectifier and inverter
Charging
5 automatic modes, manual for vented batteries, temperature compensation
Cooling
redundant fans with flow monitoring

Technical specifications

ClassificationVFI-SS-111 per IEC/EN 62040
Controldual DSP + PLD for the rectifier and inverter
Charging5 automatic modes, manual for vented batteries, temperature compensation
Coolingredundant fans with flow monitoring
CommunicationModbus RS232/RS485, Ethernet

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The rectifier and inverter have separate control loops on a dual DSP and PLD programmable logic. The charger works in 5 automatic modes and supports manual control for vented serviced batteries and temperature compensation of the charge voltage. Manual mode is needed for equalizing charge, when staff service the battery in a separate room. The fans are redundant and their flow is monitored, so the failure of one of them does not lead to overheating and shutdown. For integration into process control systems there is Modbus over RS232 or RS485 and an Ethernet port. Protection selectivity means that a short circuit in one outgoing line does not de-energize the other consumers.

How to choose

The power and battery voltage for DPS are agreed per project, so the request should state the load, the battery type and the short-circuit current needed for selectivity. Vented batteries require the manual charge mode, while sealed ones work in the automatic modes. For ordinary server rooms with no selectivity requirements, the modular HELIOS-TH of 10–100 kVA or IRIS+TT of 10–30 kVA will be simpler.

Request a price and lead time

DPS — industrial IGBT UPS. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Why is short-circuit tolerance important for an industrial UPS?

The DPS UPS delivers a short-circuit current sufficient to trip the branch breaker, so only the faulty line is disconnected.

What battery charging modes does the DPS UPS have?

There are 5 automatic modes, a manual mode for vented batteries and temperature compensation of the charge voltage.

What communication protocols does DPS support?

Modbus over RS232 or RS485, and also Ethernet for connection to SCADA.

How is cooling of the DPS UPS arranged?

The fans are redundant and fitted with airflow monitoring, so the failure of one does not stop the UPS.

Which class under IEC/EN 62040 does DPS belong to?

It is an online UPS of class VFI-SS-111, whose output does not depend on mains voltage and frequency.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.