Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

UPS AND POWER SUPPLIES

Futura industrial online UPS 5–800 kVA

The Futura industrial double-conversion UPS is available with a single-phase output of 5–50 kVA and a three-phase output of 5–800 kVA. It is installed at oil and gas facilities, in the power industry and at military sites where the load cannot tolerate an interruption of supply.

Power
1-ph. output: 5–50 kVA (SRE-…/1); 3-ph. output: 5–800 kVA (SRE-5…SRE-800) per datasheet tables
Classification
VFI per EN 62040-3
Output voltage
±1%, THD < 2%, output isolation transformer
Efficiency
> 92%

Technical specifications

Power1-ph. output: 5–50 kVA (SRE-…/1); 3-ph. output: 5–800 kVA (SRE-5…SRE-800) per datasheet tables
ClassificationVFI per EN 62040-3
Output voltage±1%, THD < 2%, output isolation transformer
Efficiency> 92%
Overload125% 10 min, 150% 1 min, 200% 0.1 s
Batteriessealed lead-acid; NiCd / Li-Ion / NaNiCl2 on request
Protection degreeIP20
StandardsEN 62040-1/-2/-3, EN 60146-1-1; NATO code (NCAGE) AD484

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The VFI class per EN 62040-3 means that the inverter supplies the load continuously and the output voltage does not depend on the mains voltage and frequency. Control is DSP-based, the output is held within ±1% at THD below 2%, and efficiency is above 92%. The output isolation transformer galvanically separates the load and makes the UPS tolerant of unbalanced and surge currents. The overload margin of 125% for 10 min, 150% for 1 min and 200% for 0.1 s covers motor starts and the tripping of protective devices. Several units are connected in parallel to increase power or for N+1 redundancy. Sealed lead-acid batteries are fitted as standard, with NiCd, Li-Ion or NaNiCl2 on request. The unit complies with EN 62040-1/-2/-3 and EN 60146-1-1, enclosure IP20.

How to choose

Futura power is selected from the datasheet tables; a single-phase output is available for 5–50 kVA, three-phase up to 800 kVA. The battery chemistry is chosen to suit conditions: NiCd tolerates cold and deep discharges, Li-Ion saves space. If a single-phase UPS of 2–10 kVA with built-in batteries for 20 min is needed, Mizar is simpler; for 1–3 h of autonomy up to 10 kVA there is Proton, and for substation operational DC networks the UC with a 24–400 V output is suitable.

Request a price and lead time

Futura industrial online UPS 5–800 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What does the VFI class mean for the Futura UPS?

Per EN 62040-3, VFI means double conversion, and the output voltage and frequency do not depend on the mains. Futura holds the output with ±1% accuracy and THD below 2%.

What overload does the Futura UPS withstand?

125% for 10 min, 150% for 1 min and 200% for 0.1 s.

Which batteries can be connected to Futura?

Sealed lead-acid as standard, NiCd, Li-Ion or NaNiCl2 on request.

Can several Futura UPS units be connected in parallel?

Yes, parallel operation of several units is provided; it increases power or gives redundancy in case one unit fails.

Does Futura have a NATO codification?

Yes, the Futura UPS has the NATO code (NCAGE) AD484 and complies with EN 62040-1/-2/-3 and EN 60146-1-1.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.