HELIOS MPW / MP2 / M2X modular UPS for data centers up to 1600 kW
Country: France · Model: HELIOS MPW / MP2 / M2X
HELIOS MPW, MP2 and M2X modular UPS units are designed for data centers and critical loads of up to 1600 kW. The system is assembled from power modules of 15, 25 or 42 kW, giving up to 294 kW in one cabinet.
- Power
- power modules 15/25/42 kW; up to 294 kW per cabinet; up to 1176 kW with 4 cabinets; MP2: up to 500 kW; M2S: 1000–1600 kW
- Topology
- online double conversion, hot-swap modules
- Scaling
- pay-as-you-grow, N+1
- Interfaces
- 10″ touch display, NetMan 208, REPO
Technical specifications
| Power | power modules 15/25/42 kW; up to 294 kW per cabinet; up to 1176 kW with 4 cabinets; MP2: up to 500 kW; M2S: 1000–1600 kW |
|---|---|
| Topology | online double conversion, hot-swap modules |
| Scaling | pay-as-you-grow, N+1 |
| Interfaces | 10″ touch display, NetMan 208, REPO |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Power and redundancy are increased by adding power and battery modules without switching off the load, on the pay-as-you-grow principle. The modules work in online double-conversion mode and are hot-swappable. Four cabinets together give up to 1176 kW, the MP2 series reaches 500 kW, and M2S covers 1000–1600 kW. The N+1 scheme keeps one module in reserve, so the failure of any one of them does not affect the supply to the servers. Control is on a 10″ touch display, the NetMan 208 network card passes status to a monitoring system, and the REPO input serves for remote emergency shutdown. For a data center built in stages, this removes the need to buy the whole rating in advance.
How to choose
The starting configuration is calculated from the current IT load plus one spare module, and the cabinet is chosen for the final power, up to 294 kW in one. The 15 kW module is advantageous for small server rooms where the growth step is small, while 42 kW modules reduce their number in large halls. For a load up to 100 kVA without such scale, HELIOS-TH is simpler. Above 1176 kW look at M2S at 1000–1600 kW.
Request a price and lead time
HELIOS MPW / MP2 / M2X modular UPS for data centers up to 1600 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the maximum power of HELIOS modular UPS units for data centers?
One cabinet gives up to 294 kW, four cabinets up to 1176 kW, and the M2S series covers 1000–1600 kW.
What power are the HELIOS MPW power modules?
Power modules of 15, 25 or 42 kW, which are replaced hot without switching off the load.
Can HELIOS MPW be expanded without stopping the data center?
Yes, power and battery modules are added without switching off the load, on the pay-as-you-grow principle with N+1 redundancy.
What is the power of the HELIOS MP2 UPS?
The MP2 series is designed for systems of up to 500 kW.
What monitoring facilities does HELIOS MPW have?
A 10″ touch display, the NetMan 208 network card and the REPO remote emergency shutdown input.