UPSaver — high-power modular UPS up to 2.67 MVA

A megawatt-class modular UPS built from 333 kVA modules, up to 2.67 MVA in one block and up to 21 MVA in parallel. Efficiency is 97.2 % and noise stays below 65 dB. It is specified for large data centers where the white space fills up in phases.

Power
333 kVA modules; up to 2.67 MVA in a single unit; up to 21 MVA in parallel
Efficiency
97.2 %
Noise level
< 65 dB
Connection
cable or busbar, top/bottom entry

Technical specifications

Power333 kVA modules; up to 2.67 MVA in a single unit; up to 21 MVA in parallel
Efficiency97.2 %
Noise level< 65 dB
Connectioncable or busbar, top/bottom entry
Batterieslithium battery compatible
Functionspeak shaving
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

UPSaver grows module by module, and modules are added hot, without stopping the UPS. The first phase of racks gets only as many modules as it needs today, and the rest arrive as the load grows. At a 2.67 MVA load, every percentage point of efficiency is tens of kilowatts of heat that the cooling plant does not have to remove. Lithium batteries are supported, and they take less floor space and weigh less than lead-acid strings. Peak shaving covers load peaks from the battery, so the utility feed can be sized for less power. Supply and load connect by cable or busbar, from the top or bottom, to suit the hall layout. Noise below 65 dB matters when the UPS stands next to an operator room or in a space where staff work.

How to choose

To count modules, divide the load by 333 kVA and add one spare. One block covers up to 2.67 MVA, and beyond that blocks run in parallel up to 21 MVA. If the project fits within 1200 kW per cabinet, look at Keor FLEX with up to 98.6 % efficiency in double conversion. For sites up to 2.1 MVA built from 250 or 300 kVA blocks, Keor XPE is a better match.

Request a price and lead time

UPSaver — high-power modular UPS up to 2.67 MVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power does UPSaver deliver in one block and in parallel?

Up to 2.67 MVA in one block and up to 21 MVA in a parallel system. The step size is one 333 kVA module.

What are the efficiency and noise level of UPSaver?

Efficiency is 97.2 % and noise is below 65 dB.

Does UPSaver work with lithium-ion batteries?

Yes, the UPS is compatible with lithium batteries and supports peak shaving.

Can a module be added to UPSaver without dropping the load?

Yes, 333 kVA modules are added hot while the UPS keeps feeding the load.

How are cables brought into UPSaver?

By cable or busbar, from the top or bottom. The choice follows the raised floor or overhead trays of the hall.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.