Keor MOD RI — modular 19″ rack UPS, 25/50 kVA
Country: France · Model: Keor MOD RI
A three-phase modular UPS for 25 or 50 kVA with N+1 redundancy that mounts directly in a 19″ server cabinet 1000 or 1200 mm deep. The 25 kVA version runs on 2 power modules and the 50 kVA version on 3, with an output power factor of 1. It targets edge data centers and server rooms that have no separate UPS room.
- Power
- 25 kVA N+1 (2 modules) or 50 kVA N+1 (3 modules)
- Efficiency
- up to 96.8 % (module), up to 99 % in ECO mode
- Output power factor (cos φ)
- 1
- Design
- for 19″ cabinets 1,000/1,200 mm deep
Technical specifications
| Power | 25 kVA N+1 (2 modules) or 50 kVA N+1 (3 modules) |
|---|---|
| Efficiency | up to 96.8 % (module), up to 99 % in ECO mode |
| Output power factor (cos φ) | 1 |
| Design | for 19″ cabinets 1,000/1,200 mm deep |
| Batteries | built-in, hot-swappable drawers |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504403000 |
| CN code (EU) | 85044095 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Keor MOD RI goes into the same rack as the IT equipment and takes part of its height instead of a separate floor-standing enclosure. In the N+1 layout one module is always spare, so if it fails the remaining modules keep the load running. Power module efficiency is up to 96.8 %, and up to 99 % in ECO mode, which makes sense on a stable city grid. Batteries are built into the cabinet, and battery drawers are hot-swapped without stopping the servers. With an output power factor of 1, the 25 kVA rating equals 25 kW of real power, which makes it easy to check against the power supply ratings of the servers. Check the cabinet depth before ordering, as racks shallower than 1000 mm will not fit.
How to choose
The version follows the load of the rack or row in kW. Up to 25 kW the 2-module version is enough, and up to 50 kW you need the 3-module version, both with N+1 already built in. If the load is larger or the UPS can stand on the floor, look at the floor-standing Keor MP for 10–200 kVA. For a small server room with a three-phase supply at 10–40 kVA, there is HPi 33 EVO.
Request a price and lead time
Keor MOD RI — modular 19″ rack UPS, 25/50 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What cabinet depth does Keor MOD RI need?
It fits 19″ cabinets 1000 or 1200 mm deep.
How many modules does Keor MOD RI need for 50 kVA N+1?
3 power modules, while 25 kVA N+1 needs 2.
What is Keor MOD RI efficiency in ECO mode?
Up to 99 %, while the power module itself reaches up to 96.8 %.
Where are the Keor MOD RI batteries located?
The batteries are built into the cabinet, and battery drawers are hot-swapped without dropping the load.
How many kW does the 50 kVA Keor MOD RI deliver?
The output power factor is 1, so 50 kVA corresponds to 50 kW of real power.