Keor MOD RI — modular 19″ rack UPS, 25/50 kVA

A three-phase modular UPS for 25 or 50 kVA with N+1 redundancy that mounts directly in a 19″ server cabinet 1000 or 1200 mm deep. The 25 kVA version runs on 2 power modules and the 50 kVA version on 3, with an output power factor of 1. It targets edge data centers and server rooms that have no separate UPS room.

Power
25 kVA N+1 (2 modules) or 50 kVA N+1 (3 modules)
Efficiency
up to 96.8 % (module), up to 99 % in ECO mode
Output power factor (cos φ)
1
Design
for 19″ cabinets 1,000/1,200 mm deep

Technical specifications

Power25 kVA N+1 (2 modules) or 50 kVA N+1 (3 modules)
Efficiencyup to 96.8 % (module), up to 99 % in ECO mode
Output power factor (cos φ)1
Designfor 19″ cabinets 1,000/1,200 mm deep
Batteriesbuilt-in, hot-swappable drawers
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Keor MOD RI goes into the same rack as the IT equipment and takes part of its height instead of a separate floor-standing enclosure. In the N+1 layout one module is always spare, so if it fails the remaining modules keep the load running. Power module efficiency is up to 96.8 %, and up to 99 % in ECO mode, which makes sense on a stable city grid. Batteries are built into the cabinet, and battery drawers are hot-swapped without stopping the servers. With an output power factor of 1, the 25 kVA rating equals 25 kW of real power, which makes it easy to check against the power supply ratings of the servers. Check the cabinet depth before ordering, as racks shallower than 1000 mm will not fit.

How to choose

The version follows the load of the rack or row in kW. Up to 25 kW the 2-module version is enough, and up to 50 kW you need the 3-module version, both with N+1 already built in. If the load is larger or the UPS can stand on the floor, look at the floor-standing Keor MP for 10–200 kVA. For a small server room with a three-phase supply at 10–40 kVA, there is HPi 33 EVO.

Request a price and lead time

Keor MOD RI — modular 19″ rack UPS, 25/50 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What cabinet depth does Keor MOD RI need?

It fits 19″ cabinets 1000 or 1200 mm deep.

How many modules does Keor MOD RI need for 50 kVA N+1?

3 power modules, while 25 kVA N+1 needs 2.

What is Keor MOD RI efficiency in ECO mode?

Up to 99 %, while the power module itself reaches up to 96.8 %.

Where are the Keor MOD RI batteries located?

The batteries are built into the cabinet, and battery drawers are hot-swapped without dropping the load.

How many kW does the 50 kVA Keor MOD RI deliver?

The output power factor is 1, so 50 kVA corresponds to 50 kW of real power.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.