Megaline Rack — modular 19″ rack UPS, 1.25–5 kVA
Country: France · Model: Megaline Rack
The rack version of the modular Megaline UPS, rated 1,250–5,000 VA for 19″ server cabinets. It is an online double-conversion VFI-111 design with N+X redundancy, and it goes into the same cabinet as the servers and switches.
- Power
- 1,250–5,000 VA
- Topology
- online, double conversion VFI-111
- Design
- 19″ rack
- Redundancy
- N+X
Technical specifications
| Power | 1,250–5,000 VA |
|---|---|
| Topology | online, double conversion VFI-111 |
| Design | 19″ rack |
| Redundancy | N+X |
| Batteries | VRLA, internal or in external cabinets |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504403000 |
| CN code (EU) | 85044095 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Megaline Rack builds its power from modules, and N+X redundancy comes from fitting more modules than the load needs. If one module fails, the rest carry on and the server never notices. The VFI class means output voltage and frequency do not depend on the mains, since the inverter runs all the time and sags, spikes and frequency drift stay on the input side. VRLA batteries fit inside the case or in external cabinets, the latter when runtime beyond the standard is needed. The UPS shares the 19″ cabinet with the servers, which keeps power leads short and removes the need for a separate UPS room. Plan for battery weight and mount the unit at the bottom of the cabinet.
How to choose
Count modules from the cabinet load in VA and add at least one more for N+1, so with 5,000 VA in the chassis the protected power sits one module below the ceiling. When single-phase load outgrows the rack, take the floor-standing Megaline from the same line. A 19″ cabinet with a three-phase feed and a 25 or 50 kVA load is a job for Keor MOD RI, with module efficiency up to 96.8 %.
Request a price and lead time
Megaline Rack — modular 19″ rack UPS, 1.25–5 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What power ratings does Megaline Rack come in?
1,250–5,000 VA, built up from power modules inside the rack chassis.
What redundancy does Megaline Rack offer?
N+X at the power module level, meaning one or more modules are fitted beyond what the load needs.
Where do the Megaline Rack batteries go?
The VRLA batteries sit inside the case or in external cabinets when longer runtime is needed.
What does the VFI-111 class of Megaline Rack mean?
It marks an online double-conversion UPS whose output voltage and frequency do not depend on the mains.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.