Keor MOD — modular three-phase UPS, 25–250 kW

A modular three-phase online UPS for data centers, rated 25–250 kW and up to 600 kW in parallel. It is built from 25 kW power modules 2U high, expands to 24 modules, and modules swap out with the load still running.

Power
25–250 kW; up to 600 kW in parallel
Power module
25 kW, 2U
Efficiency
up to 96.8 % (module), up to 99 % in ECO mode
Output power factor (cos φ)
1

Technical specifications

Power25–250 kW; up to 600 kW in parallel
Power module25 kW, 2U
Efficiencyup to 96.8 % (module), up to 99 % in ECO mode
Output power factor (cos φ)1
RedundancyN+1, hot-swappable modules
Batteriesbuilt-in VRLA up to 125 kW
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Keor MOD has a distributed bypass, with one inside each power module, so there is no single point of failure in a central static bypass. Module efficiency is up to 96.8 %, or up to 99 % in ECO, and the output power factor is 1, so the kW rating matches kVA. ECO mode suits sites with a stable grid where the energy bill matters most, while double conversion stays on for critical IT load. Redundancy is N+1, and modules are hot-swapped with the load running, so a service engineer replaces a module on site without stopping the data center. For ratings up to 125 kW, VRLA batteries fit inside the cabinet, and above that separate battery cabinets are used. The 25 kW step suits a data center that fills up with racks over time.

How to choose

Count modules as the IT load divided by 25 kW, then add one for N+1. If everything must fit a 19″ server cabinet 1,000/1,200 mm deep, take Keor MOD RI at 25 or 50 kVA. Once the load passes 600 kW, move to Keor MOD+ with 60 kW modules 3U high and scaling to 1.8 MW, or to Keor FLEX at up to 1,200 kW in one cabinet.

Request a price and lead time

Keor MOD — modular three-phase UPS, 25–250 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the rating of a Keor MOD power module?

25 kW in a 2U module, with up to 24 modules in a system.

How far does Keor MOD scale?

One UPS goes up to 250 kW, and a parallel system up to 600 kW.

Does Keor MOD have built-in batteries?

Yes, built-in VRLA batteries are available for ratings up to 125 kW.

What is the efficiency of Keor MOD in ECO mode?

Up to 99 % in ECO and up to 96.8 % per module in double conversion.

Can a Keor MOD module be replaced without shutting down the load?

Yes, modules are hot-swappable, and N+1 redundancy carries the load while one is out.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.