Keor MOD — modular three-phase UPS, 25–250 kW
Country: France · Model: Keor MOD
A modular three-phase online UPS for data centers, rated 25–250 kW and up to 600 kW in parallel. It is built from 25 kW power modules 2U high, expands to 24 modules, and modules swap out with the load still running.
- Power
- 25–250 kW; up to 600 kW in parallel
- Power module
- 25 kW, 2U
- Efficiency
- up to 96.8 % (module), up to 99 % in ECO mode
- Output power factor (cos φ)
- 1
Technical specifications
| Power | 25–250 kW; up to 600 kW in parallel |
|---|---|
| Power module | 25 kW, 2U |
| Efficiency | up to 96.8 % (module), up to 99 % in ECO mode |
| Output power factor (cos φ) | 1 |
| Redundancy | N+1, hot-swappable modules |
| Batteries | built-in VRLA up to 125 kW |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504403000 |
| CN code (EU) | 85044095 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Keor MOD has a distributed bypass, with one inside each power module, so there is no single point of failure in a central static bypass. Module efficiency is up to 96.8 %, or up to 99 % in ECO, and the output power factor is 1, so the kW rating matches kVA. ECO mode suits sites with a stable grid where the energy bill matters most, while double conversion stays on for critical IT load. Redundancy is N+1, and modules are hot-swapped with the load running, so a service engineer replaces a module on site without stopping the data center. For ratings up to 125 kW, VRLA batteries fit inside the cabinet, and above that separate battery cabinets are used. The 25 kW step suits a data center that fills up with racks over time.
How to choose
Count modules as the IT load divided by 25 kW, then add one for N+1. If everything must fit a 19″ server cabinet 1,000/1,200 mm deep, take Keor MOD RI at 25 or 50 kVA. Once the load passes 600 kW, move to Keor MOD+ with 60 kW modules 3U high and scaling to 1.8 MW, or to Keor FLEX at up to 1,200 kW in one cabinet.
Request a price and lead time
Keor MOD — modular three-phase UPS, 25–250 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the rating of a Keor MOD power module?
25 kW in a 2U module, with up to 24 modules in a system.
How far does Keor MOD scale?
One UPS goes up to 250 kW, and a parallel system up to 600 kW.
Does Keor MOD have built-in batteries?
Yes, built-in VRLA batteries are available for ratings up to 125 kW.
What is the efficiency of Keor MOD in ECO mode?
Up to 99 % in ECO and up to 96.8 % per module in double conversion.
Can a Keor MOD module be replaced without shutting down the load?
Yes, modules are hot-swappable, and N+1 redundancy carries the load while one is out.