Keor MOD+ — modular three-phase UPS, 420/600 kW

A three-phase modular online UPS in 420 and 600 kW cabinets, with a multi-cabinet system scaling to 1.8 MW. It is built from 60 kW power modules 3U high, at up to 96 % efficiency. Typical sites are critical facilities, data centers and plants with loads of several hundred kilowatts.

Power
420 and 600 kW cabinets; scalable up to 1.8 MW
Power module
60 kW, 3U
Efficiency
up to 96 %
iTHD
< 3 %

Technical specifications

Power420 and 600 kW cabinets; scalable up to 1.8 MW
Power module60 kW, 3U
Efficiencyup to 96 %
iTHD< 3 %
Output power factor (cos φ)1 at 40 °C
BatteriesVRLA or lithium-ion
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Cabinet power is set by the number of 60 kW power modules, and one module above the load gives N+1 redundancy. Power modules and static bypass modules are hot-swappable. Input current is nearly undistorted, with iTHD below 3 %, so the UPS does not load the upstream transformer and diesel generator with harmonics. The output power factor of 1 holds at 40 °C, so the kW rating does not drop in a hot room. It runs on VRLA or lithium-ion batteries, chosen by battery room area and required service life. A 3U module slides out from the front, and a service engineer swaps it on site.

How to choose

Take the 420 kW cabinet if the load plus redundancy fits its modules, and the 600 kW cabinet if you need room to grow. Above 600 kW, cabinets are combined into a system of up to 1.8 MW. Up to 160 kW, TriMOD with single-phase modules costs less. If one cabinet must carry up to 1200 kW, or up to 98.6 % efficiency in double conversion matters, compare with Keor FLEX.

Request a price and lead time

Keor MOD+ — modular three-phase UPS, 420/600 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How far does Keor MOD+ scale?

Cabinets come in 420 and 600 kW, and the system grows to 1.8 MW.

What is the rating of a Keor MOD+ power module?

60 kW at a height of 3U.

Which batteries work with Keor MOD+?

Lead-acid VRLA or lithium-ion.

What input current distortion does Keor MOD+ produce?

iTHD is below 3 %, so the UPS puts little harmonic load on the generator and transformer.

Does Keor MOD+ derate at high temperature?

The maker states an output power factor of 1 at 40 °C, so the kW rating holds up to that temperature.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.