Keor MOD+ — modular three-phase UPS, 420/600 kW
Country: France · Model: Keor MOD+
A three-phase modular online UPS in 420 and 600 kW cabinets, with a multi-cabinet system scaling to 1.8 MW. It is built from 60 kW power modules 3U high, at up to 96 % efficiency. Typical sites are critical facilities, data centers and plants with loads of several hundred kilowatts.
- Power
- 420 and 600 kW cabinets; scalable up to 1.8 MW
- Power module
- 60 kW, 3U
- Efficiency
- up to 96 %
- iTHD
- < 3 %
Technical specifications
| Power | 420 and 600 kW cabinets; scalable up to 1.8 MW |
|---|---|
| Power module | 60 kW, 3U |
| Efficiency | up to 96 % |
| iTHD | < 3 % |
| Output power factor (cos φ) | 1 at 40 °C |
| Batteries | VRLA or lithium-ion |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504403000 |
| CN code (EU) | 85044095 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Cabinet power is set by the number of 60 kW power modules, and one module above the load gives N+1 redundancy. Power modules and static bypass modules are hot-swappable. Input current is nearly undistorted, with iTHD below 3 %, so the UPS does not load the upstream transformer and diesel generator with harmonics. The output power factor of 1 holds at 40 °C, so the kW rating does not drop in a hot room. It runs on VRLA or lithium-ion batteries, chosen by battery room area and required service life. A 3U module slides out from the front, and a service engineer swaps it on site.
How to choose
Take the 420 kW cabinet if the load plus redundancy fits its modules, and the 600 kW cabinet if you need room to grow. Above 600 kW, cabinets are combined into a system of up to 1.8 MW. Up to 160 kW, TriMOD with single-phase modules costs less. If one cabinet must carry up to 1200 kW, or up to 98.6 % efficiency in double conversion matters, compare with Keor FLEX.
Request a price and lead time
Keor MOD+ — modular three-phase UPS, 420/600 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How far does Keor MOD+ scale?
Cabinets come in 420 and 600 kW, and the system grows to 1.8 MW.
What is the rating of a Keor MOD+ power module?
60 kW at a height of 3U.
Which batteries work with Keor MOD+?
Lead-acid VRLA or lithium-ion.
What input current distortion does Keor MOD+ produce?
iTHD is below 3 %, so the UPS puts little harmonic load on the generator and transformer.
Does Keor MOD+ derate at high temperature?
The maker states an output power factor of 1 at 40 °C, so the kW rating holds up to that temperature.