PowerUPS 9000 — modular three-phase UPS 1250–1800 kW

Three-phase UPS with high power density, rated 1250–1800 kW in a compact floor-standing enclosure. It targets large data centers and AI loads and comes in CE and UL versions.

Power
1250–1800 kW (including Compact and Full AI Module)
Voltage
380/400/415 V, 50 Hz (CE)
Design
IP20, floor-standing
Configuration
single or multi-module

Technical specifications

Power1250–1800 kW (including Compact and Full AI Module)
Voltage380/400/415 V, 50 Hz (CE)
DesignIP20, floor-standing
Configurationsingle or multi-module
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The CE version runs on 380/400/415 V, 50 Hz networks, which matches standard three-phase distribution in Ukraine and the EU. The line includes Compact and Full AI Module versions, both within 1250–1800 kW. The IP20 enclosure stands on the floor of the electrical room or white space, which must be clean and dry. The system is built as a single unit or as a multi-module installation, depending on power and required redundancy. High power density matters in AI halls, where UPS floor area competes with racks and cooling plant. At this power, input and output connect through busway or heavy cable runs, planned together with the main switchboard layout.

How to choose

Start from the total critical load of the hall and the redundancy scheme, then decide between one unit and a multi-module system. Below 1250 kW, EXL S1 covers 300–1250 kW as a transformerless monoblock, and EXL P1 serves 300–600 kW. PowerUPS 9000 is the step for halls that need 1250–1800 kW per system, with Compact or Full AI Module chosen by space and load profile. For projects outside European grids, specify the UL version.

Request a price and lead time

PowerUPS 9000 — modular three-phase UPS 1250–1800 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the power rating of the PowerUPS 9000 UPS?

From 1250 to 1800 kW, including the Compact and Full AI Module versions.

What voltage does the CE version of PowerUPS 9000 use?

380/400/415 V, 50 Hz, which matches standard three-phase networks in Ukraine and the EU.

What is the enclosure rating of PowerUPS 9000?

IP20, floor-standing, for a clean electrical room.

Can PowerUPS 9000 be configured with several modules?

Yes, it is built as a single unit or as a multi-module system, depending on power and redundancy.

Is PowerUPS 9000 suitable for AI data centers?

Yes, the line has a Full AI Module version, and the UPS is built for dense AI and data center loads of 1250–1800 kW.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.