Multi Power2 / Multi Power2 Scalable — modular UPS 120–1600 kVA

The new-generation Multi Power2 and Multi Power2 Scalable modular UPS cover 120–1,600 kW per system on silicon carbide (SiC) power modules. They go into data centers, including AI loads with fast power swings. Modules are added without leaving double-conversion mode.

Power
MP2/M2X: 120–600 kW per cabinet, up to 3,600 kW (6 systems in parallel); M2S: 1,000–1,600 kW, up to 6,400 kW (4 systems in parallel)
Input/output
3:3
Power modules
silicon carbide (SiC), hot-swappable
Efficiency
up to 98.1 % (online, double conversion)

Technical specifications

PowerMP2/M2X: 120–600 kW per cabinet, up to 3,600 kW (6 systems in parallel); M2S: 1,000–1,600 kW, up to 6,400 kW (4 systems in parallel)
Input/output3:3
Power modulessilicon carbide (SiC), hot-swappable
Efficiencyup to 98.1 % (online, double conversion)
Operating temperatureup to 40 °C without derating
VersionsMP2/M2X: PCM, PC0, PCS, CBC 6 (with built-in batteries); M2S: PC0, PCS, CT0, CT2
FeaturesEfficiency Control mode, two redundant internal communication buses
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

MP2/M2X models give 120–600 kW in one cabinet, and up to 6 systems in parallel reach 3,600 kW. The scalable M2S is rated 1,000–1,600 kW and up to 6,400 kW with 4 systems in parallel. The configuration is 3:3, online double-conversion efficiency reaches 98.1 %, and power is not derated up to 40 °C. At 1 MW of load, fractions of a percent in efficiency add up to noticeable megawatt-hours per year. Modules are hot-swappable and two redundant internal communication buses run inside, so losing one does not stop the system. Efficiency Control mode keeps only as many modules running as the present load needs. MP2/M2X versions are PCM, PC0, PCS and CBC 6 with built-in batteries, while the M2S comes as PC0, PCS, CT0 and CT2. Components are developed and made in Italy.

How to choose

Pick the line by the facility's final power. MP2/M2X cover up to 600 kW per cabinet and up to 3,600 kW in parallel, while halls designed from day one for 1,000–1,600 kW per system take the M2S. If the cabinet needs built-in batteries, choose the CBC 6 version. When modularity is not needed and 250–800 kVA is enough, a monoblock NextEnergy NXE with up to 8 UPS in parallel is simpler. For loads up to 160 kVA/kW there is the Sentryum Rack with 20 kVA/kW modules.

Request a price and lead time

Multi Power2 / Multi Power2 Scalable — modular UPS 120–1600 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What efficiency does the Multi Power2 UPS reach?

Up to 98.1 % in online double-conversion mode.

How much power can Multi Power2 Scalable reach in parallel?

Up to 4 M2S systems of 1,000–1,600 kW each combine for up to 6,400 kW.

Is the Multi Power2 suitable for AI loads in data centers?

Yes, the series handles the fast power swings of AI loads. It runs without derating up to 40 °C.

What is the difference between MP2/M2X and M2S?

MP2/M2X give 120–600 kW per cabinet and up to 3,600 kW with 6 systems. The M2S is rated 1,000–1,600 kW and up to 6,400 kW with 4 systems.

Can a Multi Power2 power module be replaced without shutdown?

Yes, the SiC modules are hot-swappable while the load stays on double conversion.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.