Multi Power2 / Multi Power2 Scalable — modular UPS 120–1600 kVA
Country: Italy · Model: Multi Power2 / Multi Power2 Scalable
The new-generation Multi Power2 and Multi Power2 Scalable modular UPS cover 120–1,600 kW per system on silicon carbide (SiC) power modules. They go into data centers, including AI loads with fast power swings. Modules are added without leaving double-conversion mode.
- Power
- MP2/M2X: 120–600 kW per cabinet, up to 3,600 kW (6 systems in parallel); M2S: 1,000–1,600 kW, up to 6,400 kW (4 systems in parallel)
- Input/output
- 3:3
- Power modules
- silicon carbide (SiC), hot-swappable
- Efficiency
- up to 98.1 % (online, double conversion)
Technical specifications
| Power | MP2/M2X: 120–600 kW per cabinet, up to 3,600 kW (6 systems in parallel); M2S: 1,000–1,600 kW, up to 6,400 kW (4 systems in parallel) |
|---|---|
| Input/output | 3:3 |
| Power modules | silicon carbide (SiC), hot-swappable |
| Efficiency | up to 98.1 % (online, double conversion) |
| Operating temperature | up to 40 °C without derating |
| Versions | MP2/M2X: PCM, PC0, PCS, CBC 6 (with built-in batteries); M2S: PC0, PCS, CT0, CT2 |
| Features | Efficiency Control mode, two redundant internal communication buses |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504403000 |
| CN code (EU) | 85044095 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
MP2/M2X models give 120–600 kW in one cabinet, and up to 6 systems in parallel reach 3,600 kW. The scalable M2S is rated 1,000–1,600 kW and up to 6,400 kW with 4 systems in parallel. The configuration is 3:3, online double-conversion efficiency reaches 98.1 %, and power is not derated up to 40 °C. At 1 MW of load, fractions of a percent in efficiency add up to noticeable megawatt-hours per year. Modules are hot-swappable and two redundant internal communication buses run inside, so losing one does not stop the system. Efficiency Control mode keeps only as many modules running as the present load needs. MP2/M2X versions are PCM, PC0, PCS and CBC 6 with built-in batteries, while the M2S comes as PC0, PCS, CT0 and CT2. Components are developed and made in Italy.
How to choose
Pick the line by the facility's final power. MP2/M2X cover up to 600 kW per cabinet and up to 3,600 kW in parallel, while halls designed from day one for 1,000–1,600 kW per system take the M2S. If the cabinet needs built-in batteries, choose the CBC 6 version. When modularity is not needed and 250–800 kVA is enough, a monoblock NextEnergy NXE with up to 8 UPS in parallel is simpler. For loads up to 160 kVA/kW there is the Sentryum Rack with 20 kVA/kW modules.
Request a price and lead time
Multi Power2 / Multi Power2 Scalable — modular UPS 120–1600 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What efficiency does the Multi Power2 UPS reach?
Up to 98.1 % in online double-conversion mode.
How much power can Multi Power2 Scalable reach in parallel?
Up to 4 M2S systems of 1,000–1,600 kW each combine for up to 6,400 kW.
Is the Multi Power2 suitable for AI loads in data centers?
Yes, the series handles the fast power swings of AI loads. It runs without derating up to 40 °C.
What is the difference between MP2/M2X and M2S?
MP2/M2X give 120–600 kW per cabinet and up to 3,600 kW with 6 systems. The M2S is rated 1,000–1,600 kW and up to 6,400 kW with 4 systems.
Can a Multi Power2 power module be replaced without shutdown?
Yes, the SiC modules are hot-swappable while the load stays on double conversion.