SLC ADAPT2 / ADAPT X — modular online UPS 10–1500 kVA
Country: Spain · Model: SLC ADAPT2 / ADAPT X
A modular online UPS for data centers in which power is increased with power modules up to 500 kVA in one system and up to 1500 kVA with 3 systems in parallel. Modules are replaced and added without switching off the load.
- Modules
- 10 and 15 kW (rack, 2U); 25 and 50 kVA (cabinet); ADAPT X — 10/15/25 kW
- System power
- up to 500 kVA in a system, up to 1500 kVA with 3 systems in parallel
- Technology
- three-level IGBT inverter, DSP
- Service
- hot-swap modules, pay as you grow
Technical specifications
| Modules | 10 and 15 kW (rack, 2U); 25 and 50 kVA (cabinet); ADAPT X — 10/15/25 kW |
|---|---|
| System power | up to 500 kVA in a system, up to 1500 kVA with 3 systems in parallel |
| Technology | three-level IGBT inverter, DSP |
| Service | hot-swap modules, pay as you grow |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The range has two module formats. The rack modules of 10 and 15 kW are 2U high, the cabinet ones are designed for 25 and 50 kVA, and the ADAPT X variant has modules of 10, 15 and 25 kW. Each module contains a three-level IGBT inverter with digital DSP control. Hot swap makes it possible to pull out a faulty module while the others hold the load, so a repair does not stop the server room. The pay as you grow principle means that at the start as many modules are bought as are needed now, and the rest are added to free slots as the data center grows. An additional module above the calculated power gives a reserve in case one of them fails.
How to choose
The module size is chosen by the growth step. Modules of 10 or 15 kW are convenient for server rooms that grow gradually, and modules of 25 and 50 kVA reduce the number of units in a large system. The limit of one system is 500 kVA, and for a larger load up to 1500 kVA 3 systems are combined in parallel. If the power is stable and modularity is not needed, it is simpler to install a monoblock three-phase UPS of the CUBE or X-PERT series.
Request a price and lead time
SLC ADAPT2 / ADAPT X — modular online UPS 10–1500 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the maximum power of the SLC ADAPT2?
Up to 500 kVA in one system and up to 1500 kVA with parallel operation of 3 systems.
Which modules are available for ADAPT2 and ADAPT X?
For ADAPT2 there are rack modules of 10 and 15 kW of 2U height and cabinet ones of 25 and 50 kVA. ADAPT X uses modules of 10, 15 and 25 kW.
Can an ADAPT2 module be replaced without switching off the load?
Yes, the modules support hot swap, and the load stays powered by the remaining modules.
What does pay as you grow mean for a modular UPS?
The system is bought for the current load and modules are added as the data center grows, without replacing the cabinet.