UPS7000HX-T4 / T3 high-power online UPS 400–2500 kVA
Country: Japan · Model: UPS7000HX-T4 / T3
High-power online UPS units for data centers, semiconductor plants and financial centers, where a power failure is unacceptable. The UPS7000HX-T4 is made in 400–2500 kVA for a three-phase four-wire 380/400/415 V network, and the UPS7000HX-T3 at 500 kVA is designed for a three-wire one and is about 40 % lighter than previous models.
- Type
- online (double conversion), transformerless
- Power
- UPS7000HX-T4 — 400–2500 kVA (3 ph, 4 wire); UPS7000HX-T3 — 500 kVA (3 ph, 3 wire)
- Input/output
- 380/400/415 V ±15 %, 50/60 Hz ±5 %
- Efficiency
- 96.5 % (T4)
Technical specifications
| Type | online (double conversion), transformerless |
|---|---|
| Power | UPS7000HX-T4 — 400–2500 kVA (3 ph, 4 wire); UPS7000HX-T3 — 500 kVA (3 ph, 3 wire) |
| Input/output | 380/400/415 V ±15 %, 50/60 Hz ±5 % |
| Efficiency | 96.5 % (T4) |
| Input cos φ | > 0.99 |
| Output voltage accuracy | < ±1 %; dynamic < ±5 % |
| Distortion | < 2 % (linear), < 3 % (non-linear load, IEC 62040-3) |
| Overload | 125 % for 10 min, 150 % for 1 min |
| Battery | 480–528 V DC (240–264 cells) |
| Dimensions T4/500 | 1630 × 1000 × 1950 mm |
| Topology | three-level AT-NPC on in-house RB-IGBTs |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
An efficiency of 96.5 % is obtained by the three-level AT-NPC topology (T-type with neutral point clamping) on reverse-blocking RB-IGBTs and transformerless isolation through DC link voltage control. The input power factor is above 0.99, the input and bypass voltage tolerance is ±15 %, and the frequency tolerance ±5 %. The output voltage is held to an accuracy better than ±1 %, the dynamic deviation is below ±5 %, and distortion is below 2 % on a linear and below 3 % on a non-linear load per IEC 62040-3. The rated load power factor is 0.9 (0.7–1.0 permitted), crest factor up to 3. The rated battery voltage is 480–528 V, that is 240–264 lead-acid cells. There are synchronous transfer to bypass, parallel and standby redundancy, soft start to limit inrush current, power walk-in for operation from a diesel generator, estimation of remaining battery life and optional SNMP.
How to choose
The model is chosen by network and power. The UPS7000HX-T4 is needed for a three-phase four-wire network and the 400–2500 kVA range, and the UPS7000HX-T3 at 500 kVA for a three-wire one. The overload is 125 % for 10 min and 150 % for 1 min, so short peak loads fit within this margin. For site planning take the dimensions of the T4 at 500 kVA, 1630 × 1000 × 1950 mm. For a 480 V network in North America a separate UPS7000HX-T3U series is made at 300, 400 and 500 kVA.
Request a price and lead time
UPS7000HX-T4 / T3 high-power online UPS 400–2500 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the power of the UPS7000HX-T4?
From 400 to 2500 kVA for a three-phase four-wire 380/400/415 V network.
What is the efficiency of the UPS7000HX series?
96.5 % in the T4 model, achieved by the three-level AT-NPC topology on reverse-blocking RB-IGBTs.
What are the dimensions of the UPS7000HX-T4 at 500 kVA?
1630 × 1000 × 1950 mm. The compact design reduces the floor area taken by the utility equipment.
What battery voltage is needed for the UPS7000HX?
480–528 V DC, that is 240–264 lead-acid cells.
What is the output voltage distortion factor per IEC 62040-3?
Below 2 % on a linear and below 3 % on a non-linear load.