GXT MT+ EX — single-phase online UPS 6–10 kVA
Country: USA · Model: GXT MT+ EX
Transformerless single-phase online UPS rated 6–10 kVA with double conversion and up to 93% efficiency. It fits sites where runtime is built from a flexibly sized battery, such as telecom nodes and remote sites with a generator.
- Power
- 6–10 kVA
- Efficiency
- up to 93%
- Input power factor
- 0.99
- Output power factor
- 0.9
Technical specifications
| Power | 6–10 kVA |
|---|---|
| Efficiency | up to 93% |
| Input power factor | 0.99 |
| Output power factor | 0.9 |
| Rectifier | IGBT, DSP control |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504403000 |
| CN code (EU) | 85044095 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
The rectifier uses IGBTs under DSP control. Input power factor is 0.99, so the UPS barely distorts mains current and does not overload a generator. Output power factor is 0.9, which puts real power below the kVA rating. Charging current is adjustable, which lets the UPS work with batteries of different capacity. A large external battery bank is therefore recharged in reasonable time instead of trickling for days. With no transformer the unit is lighter than a transformer-based machine of the same rating, easier to deliver and install.
How to choose
The choice between 6 and 10 kVA follows the real load, counting the 0.9 output power factor. Take MT+ EX when runtime comes from a large external battery bank, since the adjustable charger can be matched to it. If the load needs galvanic isolation, the alternative is GXT MTX+ CB at 6 kVA with a built-in transformer, while GXT5 covers 5–10 kVA in a 5U rack/tower chassis. For N+1 redundancy in one frame, the modular APS at 5–20 kVA fits.
Request a price and lead time
GXT MT+ EX — single-phase online UPS 6–10 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the efficiency of GXT MT+ EX?
Up to 93% in online double-conversion mode.
What is the input power factor of GXT MT+ EX 10 kVA?
Input power factor is 0.99, output is 0.9.
Can the charging current of the GXT MT+ EX UPS be adjusted?
Yes, charging current is adjustable on all 6–10 kVA models.
Does GXT MT+ EX work with a diesel generator?
Yes, with a 0.99 input power factor the IGBT rectifier draws near-sinusoidal current and does not overload the generator.
Is GXT MT+ EX transformerless?
Yes, it is a transformerless double-conversion UPS rated 6–10 kVA.
Similar products
REQUEST
Need a price, lead time or replacement?