Online UPS rated 6,000 VA / 6,000 W with a power factor of 1.0 and an isolation transformer in the same enclosure. It feeds sensitive equipment that needs galvanic isolation from the mains, such as laboratory instruments and control systems.

Power
6,000 VA / 6,000 W
Voltage
208/220/230/240 V
Features
built-in isolation transformer, common battery for parallel UPS

Technical specifications

Power6,000 VA / 6,000 W
Voltage208/220/230/240 V
Featuresbuilt-in isolation transformer, common battery for parallel UPS
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504403000
CN code (EU)85044095

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Output voltage is set to 208, 220, 230 or 240 V, so one model serves a local 230 V network as well as equipment built for other grids. The isolation transformer sits inside the enclosure, so no separate cabinet or extra floor space is needed for it. It separates the load from the mains neutral, which helps where the supply has a noisy or floating neutral-to-earth voltage. Several of these UPS units can run in parallel on a common battery, which cuts the number of battery strings and the space they take. Online topology means continuous double conversion with no transfer to battery, so the load sees no break when the mains fail.

How to choose

The deciding question is whether the load needs galvanic isolation. If it does not, GXT5 at 5–10 kVA in a 5U rack/tower chassis covers the same power. When one 6 kVA unit is not enough, paralleling MTX+ CB units on a common battery raises capacity, while the modular APS reaches 20 kVA with N+1 inside one frame. For industrial sites with motor starts and inrush current look at PowerUPS 6000 Industrial, rated 6–200 kVA.

Request a price and lead time

GXT MTX+ CB 6 kVA — online UPS with isolation transformer. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the power factor of GXT MTX+ CB 6 kVA?

The power factor is 1.0, so 6,000 VA gives 6,000 W of real power and the load can be sized directly in watts.

What voltages does the GXT MTX+ CB UPS support?

It works at 208, 220, 230 and 240 V, with the value chosen to match the site network.

Can GXT MTX+ CB units be paralleled on one battery?

Yes, parallel 6 kVA units can share a common battery, so the battery bank is not duplicated for each UPS.

Why does a UPS need a built-in isolation transformer?

It galvanically separates the load from the mains, blocks common-mode noise and gives a clean local neutral. In the MTX+ CB it sits inside the 6 kVA enclosure.

Is GXT MTX+ CB an online UPS?

Yes, it runs continuous double conversion, so there is no transfer time when the mains fail.

Similar products

UPS and power supplies

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.